Search citation statements
Paper Sections
Citation Types
Year Published
Publication Types
Relationship
Authors
Journals
This paper examines the dynamics and control involved in the active removal of a large space debris-Envisat. In the light of European Space Agaency's e.deorbit mission, the current mission scenario consists of a chaser satellite, synchronising, capturing and detumbling the large uncooperative debris. A unique multibody approach based on floating frames is used to model the Flexible Multibody Dynamics. The controllability characteristics of a linear PD controller and an Incremental Nonlinear Dynamic Inversion controller are also studied. From previous research, it was found that in the docked configuration, the control of the system could not be achieved due to the complex elastic dynamics originating from the large solar panel of Envisat (14.2 m). This paper focuses on achieving robust control of this phase through advanced design choices in both structural and control aspects. It was found that the inclusion of structural damping and reduction of control limits, lead to a major improvement in controllability of the system. A basic digital notch filter did not prove effective for more robust control. This is because only a high order filter could account for the low frequency vibrations. Further, it also required retuning of the controller within the flexible model. These two aspects proved to be beyond computational capabilities. A simple control strategy of introducing a dead-band in control loop improved the control response considerably by allowing the disturbing frequencies to dampen out.
This paper examines the dynamics and control involved in the active removal of a large space debris-Envisat. In the light of European Space Agaency's e.deorbit mission, the current mission scenario consists of a chaser satellite, synchronising, capturing and detumbling the large uncooperative debris. A unique multibody approach based on floating frames is used to model the Flexible Multibody Dynamics. The controllability characteristics of a linear PD controller and an Incremental Nonlinear Dynamic Inversion controller are also studied. From previous research, it was found that in the docked configuration, the control of the system could not be achieved due to the complex elastic dynamics originating from the large solar panel of Envisat (14.2 m). This paper focuses on achieving robust control of this phase through advanced design choices in both structural and control aspects. It was found that the inclusion of structural damping and reduction of control limits, lead to a major improvement in controllability of the system. A basic digital notch filter did not prove effective for more robust control. This is because only a high order filter could account for the low frequency vibrations. Further, it also required retuning of the controller within the flexible model. These two aspects proved to be beyond computational capabilities. A simple control strategy of introducing a dead-band in control loop improved the control response considerably by allowing the disturbing frequencies to dampen out.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.