1998
DOI: 10.1061/(asce)0733-9372(1998)124:8(767)
|View full text |Cite
|
Sign up to set email alerts
|

Model of Leaching Behavior from Fly Ash Landfills with Different Age Refuses

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2000
2000
2014
2014

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 25 publications
0
4
0
Order By: Relevance
“…The silicon was allowed to dry at least overnight before running the leaching test. Assembled columns were then allowed to saturate with deionized water from bottom up until the sand at the surface of the specimen appeared saturated (Huang et al, 1998). At that point, the top of the PVC column was covered with a plastic sheet to prevent evaporation and the bottom outlet in the PVC cap was closed so as to allow the specimen to equilibrate for 2 d (Buczko et al, 2004).…”
Section: Flow Through Leaching Testmentioning
confidence: 99%
“…The silicon was allowed to dry at least overnight before running the leaching test. Assembled columns were then allowed to saturate with deionized water from bottom up until the sand at the surface of the specimen appeared saturated (Huang et al, 1998). At that point, the top of the PVC column was covered with a plastic sheet to prevent evaporation and the bottom outlet in the PVC cap was closed so as to allow the specimen to equilibrate for 2 d (Buczko et al, 2004).…”
Section: Flow Through Leaching Testmentioning
confidence: 99%
“…Permeation with the DI water began immediately after the hydration period. The permeant (DI water) was exposed to the atmosphere to simulate the natural water in the normal environment [8,31,33].…”
Section: Column Leaching Test (Clt)mentioning
confidence: 99%
“…Given the complicated physical and chemical processes involved in the leaching of metal from fly ash, column studies are more advantageous than batch studies for testing the leaching behavior and contaminant transport in fly ash (Huang et al 1998), with the flexibility in manipulating flow condition, particle size selection, pore structure, and the ease to obtain hydrodynamic and transport kinetics parameters (Khodadoust et al 2011). Furthermore, column leaching experiments offer the convenience to quantify mass transfer as a function of time (Georgakopoulos et al 2002).…”
Section: Introductionmentioning
confidence: 99%