2020
DOI: 10.1109/tte.2020.3006135
|View full text |Cite
|
Sign up to set email alerts
|

Model Predictive Power Control for Bidirectional Series-Resonant Isolated DC–DC Converters With Fast Dynamic Response in Locomotive Traction System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 26 publications
(3 citation statements)
references
References 28 publications
0
3
0
Order By: Relevance
“…For the conventional EPS control, to minimize the backflow power of the DAB DC-DC converter, the internal shift ratio is calculated by the voltage conversion ratio and the rated power, then under this fixed internal shift ratio, the external shift ratio is adjusted by a closed-loop PID controller according to the output voltage error. In practical applications, the electrical parameters are uncertain [13,14], meanwhile, the load of the converter varies frequently [15,16]. However, the existing EPS control in the DAB converter calculates the internal shift ratio depending on the accurate parameters (capacitance, inductance, and rated power), thus it is difficult to get the required internal shift ratio in the practical application.…”
Section: Introductionmentioning
confidence: 99%
“…For the conventional EPS control, to minimize the backflow power of the DAB DC-DC converter, the internal shift ratio is calculated by the voltage conversion ratio and the rated power, then under this fixed internal shift ratio, the external shift ratio is adjusted by a closed-loop PID controller according to the output voltage error. In practical applications, the electrical parameters are uncertain [13,14], meanwhile, the load of the converter varies frequently [15,16]. However, the existing EPS control in the DAB converter calculates the internal shift ratio depending on the accurate parameters (capacitance, inductance, and rated power), thus it is difficult to get the required internal shift ratio in the practical application.…”
Section: Introductionmentioning
confidence: 99%
“…A small-signal model of DBSRC is further introduced in [17] and model-predictive control has been investigated in [18]. All these feedback control strategies ignore the transient state in the analysis as the converter adapts to different transfer power demands.…”
Section: Introductionmentioning
confidence: 99%
“…In recent years, with the development of power electronics technology, the application of isolated DC-DC converter in vehicle auxiliary power supply [1], microgrid [2], offshore wind power [3][4][5], electric locomotive traction [6][7][8][9][10], DC power grid [11] and other important fields is gradually increasing. Medium frequency transformer (MFT) is a key equipment of an isolated DC-DC converter [12].…”
Section: Introductionmentioning
confidence: 99%