2018
DOI: 10.1080/15361055.2017.1404340
|View full text |Cite
|
Sign up to set email alerts
|

Model Validation for Quantitative X-Ray Measurements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 32 publications
0
2
0
Order By: Relevance
“…While the tomography system is typically operated in this two-color mode, the filter configuration is flexible, and, for example, 8 different thickness filters can be used for increased spectral information. 32 This diagnostic has been absolutely calibrated, which makes comparisons to models of absolute brightness feasible. This includes bench tests to determine the exact amplification factor provided by the transimpedance amplifiers for frequencies between 1 and 100 kHz; calibration of the beryllium filter transmission using the BESSY II electron storage ring for photon energies between 1.8 and 10 keV; 33 accounting of all geometric effects such as non-normal incidence of photons; and accounting for the presence of an aluminum frame on the silicon detectors, which can change the spectral response of the detector.…”
Section: Ida Measurement Of Z Eff On Mstmentioning
confidence: 99%
See 1 more Smart Citation
“…While the tomography system is typically operated in this two-color mode, the filter configuration is flexible, and, for example, 8 different thickness filters can be used for increased spectral information. 32 This diagnostic has been absolutely calibrated, which makes comparisons to models of absolute brightness feasible. This includes bench tests to determine the exact amplification factor provided by the transimpedance amplifiers for frequencies between 1 and 100 kHz; calibration of the beryllium filter transmission using the BESSY II electron storage ring for photon energies between 1.8 and 10 keV; 33 accounting of all geometric effects such as non-normal incidence of photons; and accounting for the presence of an aluminum frame on the silicon detectors, which can change the spectral response of the detector.…”
Section: Ida Measurement Of Z Eff On Mstmentioning
confidence: 99%
“…However, we recently used ADAS to predict SXR signals in multiple energy ranges (different filters) with differing amounts of bremsstrahlung, radiative and dielectronic recombination, and line radiation, with excellent agreement to experimental data. 32 Filter, amplifier, and detector calibrations have been taken into account in the SXR forward model.…”
Section: Ida Measurement Of Z Eff On Mstmentioning
confidence: 99%