“…AGL systems require expensive maintenance and conservation work and pose power quality concerns mainly derived from luminaire failure [5]. For this reason, it is necessary to study and predict AGL system behavior using an AGL system equivalent circuit.…”
Section: Agl Systemsmentioning
confidence: 99%
See 1 more Smart Citation
“…AGL systems require expensive maintenance and conservation work and pose power quality concerns mainly derived from luminaire failure [5]. For this reason, it is necessary to study and predict AGL system behavior using an AGL system equivalent circuit.…”
Section: Agl Systemsmentioning
confidence: 99%
“…According to the safety restrictions of the International Civil Aviation Organization and the Federal Aviation Agency, luminaire failure is an important issue in AGL systems, with fast detection and location of failed luminaires posing a challenge in terms of cost-saving maintenance and safe operating policies. Computer-controlled monitoring of AGL systems is suggested in the literature for checking the status of AGL systems (including failed luminaires) [3] systems between luminaires and CCRs are an attractive solution for AGL system monitoring [3], [5], [6]. However, this technology is still not sufficiently developed for deployment.…”
Section: Introductionmentioning
confidence: 99%
“…These systems are single-phase series circuits where constant current regulators (CCRs) supply luminaires through transformers with voltages up to 5 kV (see Fig. 1) [1][2][3][4][5][6][7][8][9]. CCRs are variable voltage sources, [10,11], which provide an adjustable root mean square (rms) current according to luminaire brightness requirements and ensure circuit continuity, even in case of luminaire failure [4,6,7].…”
Section: Introductionmentioning
confidence: 99%
“…From bandwidth perspective, PLC is classified into Narrowband PLC (NB-PLC) and Broadband PLC (BB-PLC). NB-PLC is capable of providing low data rate communication and is well suited for emerging SG applications such automated meter reading (AMR) [3]. On the other hand, BB-PLC provides high data rates and is suitable to be used for the access of Internet and broadband applications.…”
Section: Introductionmentioning
confidence: 99%
“…Two other standards for PLC are IEEE P1775 "Power line Communication EquipmentElectromagnetic Compatibility (EMC) Requirements -Testing and Measurement Methods" and P1901 "IEEE P1901 Draft Standard for Broadband over Power Line Networks: Medium Access Control (MAC) and Physical Layer Specifications". Efforts are underway to extend these existing standards so as to ensure reliable performance for a broad range of SG applications [3].…”
Section: Introductionmentioning