2018
DOI: 10.1109/tpel.2017.2692276
|View full text |Cite
|
Sign up to set email alerts
|

Modeling and Analysis of a Dual-Active-Bridge-Isolated Bidirectional DC/DC Converter to Minimize RMS Current With Whole Operating Range

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
163
0
2

Year Published

2019
2019
2024
2024

Publication Types

Select...
3
3
1

Relationship

0
7

Authors

Journals

citations
Cited by 328 publications
(165 citation statements)
references
References 30 publications
0
163
0
2
Order By: Relevance
“…Assuming that the voltage conversion ratio k = U 1 /nU 2 and k > 1, the other condition k < 1 can be analyzed similarly. Six operating modes are summarized in traditional TPS scheme as follows [12]:…”
Section: Basic Principle Of Operating Mode Compartmentalizationmentioning
confidence: 99%
See 2 more Smart Citations
“…Assuming that the voltage conversion ratio k = U 1 /nU 2 and k > 1, the other condition k < 1 can be analyzed similarly. Six operating modes are summarized in traditional TPS scheme as follows [12]:…”
Section: Basic Principle Of Operating Mode Compartmentalizationmentioning
confidence: 99%
“…Compared with other phase-shift schemes, TPS scheme facilitates the most degrees of control freedom, which controls the duty ratios of H 1 and H 2 by two extra inner phase-shift ratios individually. Therefore, TPS control has become the most popular phase-shift control scheme of DAB converter in current research [11,12]. Numerous modulation strategies have been proposed to improve the performance of DAB converter.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Similar to the optimized methods for current stress, a numerical method is used to find the optimal control parameters for minimum rms of transformer current in [10]. In [11,12], the analytical expressions of the optimal control parameters are derived for minimum rms of transformer current. As a result, the optimal control method can be implemented by on-line and on-chip calculation.…”
Section: Introductionmentioning
confidence: 99%
“…However, the non-active current caused by zero power transmission is not considered in [23,24]. Similar to the optimized methods in [7][8][9][10][11][12], these optimized control methods in [21][22][23][24] are essentially still for current. In fact, the backflow power is just a portion of the non-active power transmission in DAB and the limitations of the backflow power control method are not presented.…”
Section: Introductionmentioning
confidence: 99%