Ieee Icca 2010 2010
DOI: 10.1109/icca.2010.5524330
|View full text |Cite
|
Sign up to set email alerts
|

Modeling and control of three-phase grid-connected photovoltaic inverter

Abstract: This paper presents mathematical modeling procedure of three-phase grid-connected photovoltaic inverter. This paper presents synchronous PI current control strategy and the method for adjuster design. The typical waveforms of grid voltage, current and harmonics of grid current are carried out in a 100kW photovoltaic inverter, which can provide some guidelines for engineers to analyze, design and implement.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(7 citation statements)
references
References 11 publications
0
7
0
Order By: Relevance
“…The gains from the PI controller were selected using Equations (21) and (22). The modelling and derivation of Equations (21) and (22) are similar to the referenced ones [24]. The other assumed parameters such as boost converter capacitor and switching frequency values are 3500 μF, and 4.5 kHz, respectively.…”
Section: Voltage Control Loopmentioning
confidence: 99%
See 1 more Smart Citation
“…The gains from the PI controller were selected using Equations (21) and (22). The modelling and derivation of Equations (21) and (22) are similar to the referenced ones [24]. The other assumed parameters such as boost converter capacitor and switching frequency values are 3500 μF, and 4.5 kHz, respectively.…”
Section: Voltage Control Loopmentioning
confidence: 99%
“…Electronics 2020, 9, x FOR PEER REVIEW 2 of 24 systems have recently been recognized as a leading way in the production of renewable electricity. This can produce direct energy when exposed to solar radiation without any environmental effects of pollution.…”
Section: Introductionmentioning
confidence: 99%
“…5. The two switches in same arm should never be turned "ON" simultaneously as it would lead to short circuiting of the voltage source.The DC link capacitor connects the DC-DC converters output DC power to the inverter [17][18]. A high capacitance value of DC link capacitor is selected to stabilize the DC voltage.…”
Section: Dc-ac Convertermentioning
confidence: 99%
“…2b. A closed-loop transfer function of the current control loop can be obtained as (13) which is assumed to cause a delay of 4T s [18]. By taking 4T s , the voltage control loop is designed to be four times slower than the current control…”
Section: Dc-link Voltage Control Loopmentioning
confidence: 99%
“…2 b . A closed‐loop transfer function of the current control loop can be obtained as (13) which is assumed to cause a delay of 4Ts [18]. By taking 4Ts, the voltage control loop is designed to be four times slower than the current controlGcvthinmathspaceloopfalse(sfalse)=14Tss+1 The open‐loop transfer function for voltage control is a type 2 system as described in and optimum symmetry criterion, in this case, would not give enough phase marginGdcthinmathspaceopenfalse(sfalse)=hK)(s+ω1)(s+ω2=KvPKdcτnormalvs+1τnormalvs24Tnormalss+1 Therefore, gain parameters of the PI controller are found using type 2 system compensation.…”
Section: Control Structure Design For Gcpvsmentioning
confidence: 99%