2015
DOI: 10.1109/tpel.2014.2367594
|View full text |Cite
|
Sign up to set email alerts
|

Modeling and Controller Design of a Semiisolated Multiinput Converter for a Hybrid PV/Wind Power Charger System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
32
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 69 publications
(32 citation statements)
references
References 32 publications
0
32
0
Order By: Relevance
“…In order to use battery in these systems, a bidirectional port is required to charge and discharge it . Multi input converters (MIC) can be applied to these systems to provide power from different power supplies simultaneously or individually …”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In order to use battery in these systems, a bidirectional port is required to charge and discharge it . Multi input converters (MIC) can be applied to these systems to provide power from different power supplies simultaneously or individually …”
Section: Introductionmentioning
confidence: 99%
“…7,8 Multi input converters (MIC) can be applied to these systems to provide power from different power supplies simultaneously or individually. 9 Nomenclature list of abbreviations: Multi input converter, MIC; Photovoltaic, PV; Fuel cell, FC; Continuous conduction mode, CCM; Maximum power point tracking, MPPT; Duty cycle of switch Si, di; Switching period, Ts.…”
Section: Introductionmentioning
confidence: 99%
“…Centralized controller not only provides control over individual interfacing devices but also controls the entire system such that the power balance is maintained in the system under different operating modes (Wu et al, 2011;Khaligh, Cao, & Lee, 2009;Zhao, Round, & Kolar, 2008;Chen, Liao, Hung, Ming, 2015). The usage of MPPT algorithm enables PV port to operate at maximum power point at different insolation levels.…”
Section: Introductionmentioning
confidence: 99%
“…However, the renewable energy systems are not loaded constantly, they are sometimes recommended to be integrated in order to operate the system more efficiently and economically [5][6][7][8]. Then, some engineering issues such as high installing cost, complex control structure and inefficient power-conditioning structure of the hybrid-type multiple renewable-energy systems have been emerged.…”
Section: Introductionmentioning
confidence: 99%
“…1 shows the general construction of a PV-wind hybrid renewable-energy system with distributed power conditioning converters. Each of the energy sources in the distributed Power Conditioning System (PCS) is employed with an individual DC-DC converters [5][6][7][8].…”
Section: Introductionmentioning
confidence: 99%