2017
DOI: 10.1002/rcs.1829
|View full text |Cite
|
Sign up to set email alerts
|

Modeling and evaluation of hand–eye coordination of surgical robotic system on task performance

Abstract: This hand-eye coordination model provides evidence for robotic design, surgeon training, and robotic initialization to achieve dexterous and safe manipulation in surgery.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 26 publications
0
4
0
Order By: Relevance
“…In addition, operating at wider manipulation angles can be compensated for by use of the clutch at the fingertips, which can temporarily disconnect the robotic arm guidance from the console. Manipulation angles of 60°, 90° and 120° did not have a significant effect on task performance with a laboratory‐based robotic system [20]. The clutch at the surgeon console allows the surgeon to bring his/her arms close together in ergonomic positions even if the manipulation angle is wide and the handles of the robotic instruments are far apart.…”
Section: Discussionmentioning
confidence: 99%
“…In addition, operating at wider manipulation angles can be compensated for by use of the clutch at the fingertips, which can temporarily disconnect the robotic arm guidance from the console. Manipulation angles of 60°, 90° and 120° did not have a significant effect on task performance with a laboratory‐based robotic system [20]. The clutch at the surgeon console allows the surgeon to bring his/her arms close together in ergonomic positions even if the manipulation angle is wide and the handles of the robotic instruments are far apart.…”
Section: Discussionmentioning
confidence: 99%
“…Building on the two kinematic models mentioned in Section , the master‐slave motion alignment model is shown in Figure . Since the display translates the image acquired by the laparoscope in real time, the display coordinate system can be considered to coincide with the laparoscopic coordinate system.…”
Section: Methodsmentioning
confidence: 99%
“…When operators manually manipulate a surgical robot master console by hand, they look at the slave manipulator's movement on a screen seen through the endoscope. 23,24 The master movement was processed as somatic information. However, the slave movement was processed as visual information.…”
Section: Cognitive Modelmentioning
confidence: 99%