2018
DOI: 10.1109/jestpe.2017.2715224
|View full text |Cite
|
Sign up to set email alerts
|

Modeling and Stability Analysis of VSC Internal Voltage in DC-Link Voltage Control Timescale

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
59
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 60 publications
(59 citation statements)
references
References 21 publications
0
59
0
Order By: Relevance
“…For VSC control loops as introduced in Section 2.1, the response time constant of current control is often designed around 10ms (which is closely related to the switching frequency), and those of DVC, TVC, and PLL are selected to be about ten times larger [23]. Considering the designed response time constant of different controllers, stability issues related to VSC can be classified into the DVC timescale stability problems [14][15][16]24] and the current control timescale stability problems [22,25]. For simplicity, the dynamics in these two timescales can be analyzed individually due to their relatively separated response times.…”
Section: Definition Of Dvc Timescalementioning
confidence: 99%
See 1 more Smart Citation
“…For VSC control loops as introduced in Section 2.1, the response time constant of current control is often designed around 10ms (which is closely related to the switching frequency), and those of DVC, TVC, and PLL are selected to be about ten times larger [23]. Considering the designed response time constant of different controllers, stability issues related to VSC can be classified into the DVC timescale stability problems [14][15][16]24] and the current control timescale stability problems [22,25]. For simplicity, the dynamics in these two timescales can be analyzed individually due to their relatively separated response times.…”
Section: Definition Of Dvc Timescalementioning
confidence: 99%
“…For simplicity, the dynamics in these two timescales can be analyzed individually due to their relatively separated response times. Therefore, for stability analysis in the DVC timescale, AC currents can be considered to instantaneously track their reference values [14][15][16]24]. Besides, since the filter capacitor C f mainly contributes to the high-frequency oscillations, which belong to the current control timescale [22,25], for stability analysis in the DVC timescale, the effect of the filter capacitor can be neglected [14][15][16]24].…”
Section: Definition Of Dvc Timescalementioning
confidence: 99%
“…DC/AC converters are one of the most common interfaces between the distributed generation system and the power grid. Traditional vector control strategies of DC/AC converters mainly aim to achieve a fast dynamic response [1]. Moreover, the power control of renewable energy is often set as maximum power point tracking (MPPT) in order to harvest as much energy as possible [2,3].…”
Section: Introductionmentioning
confidence: 99%
“…Thus, the need of capable control for CHBMLI is necessary to correct the output converter voltage, even under changing environmental conditions. Many control strategies and power conditioning schemes are used for controlling the dc‐link voltages of CHB‐MLI and minimizing the power quality problems in its output as reported in literature …”
Section: Introductionmentioning
confidence: 99%