The simulation of deep-submicron silicon-device manufacturing processes relies on predictive models for extended defect clusters. For submicroscopic interstitial clusters and {311} defects, an efficient and highly accurate model for process simulation has been developed and calibrated recently [1]. This model combines equations for three small interstitial clusters and two moments for {311} defects. In this work, we extend this model to include dislocation loops and to reproduce a greatly increased range of experimental data, including thermal annealing of end-of-range defects after amorphizing implants.