Modeling, Fabrication, and Testing of a 3D-Printed Coriolis Mass Flow Sensor

Abstract: This paper presents the modeling, fabrication, and testing of a 3D-printed Coriolis mass flow sensor. The sensor contains a free-standing tube with a circular cross-section printed using the LCD 3D-printing technique. The tube has a total length of 42 mm, an inner diameter of about 900 µm, and a wall thickness of approximately 230 µm. The outer surface of the tube is metalized using a Cu plating process, resulting in a low electrical resistance of 0.5 Ω. The tube is brought into vibration using an AC current i… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
6
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(6 citation statements)
references
References 25 publications
0
6
0
Order By: Relevance
“…Based on the analytical model of a U-shaped Coriolis mass-flow sensor presented in [ 24 ], the mass-flow sensitivity can be expressed as: where is the amplitude of the displacement in direction of the tube segment with length due to the Coriolis forces, is the amplitude of the angular displacement in the actuation mode, is the mass-flow rate, and is the total mass of the tube and the fluid inside the tube. and are the length of the tube in and direction as indicated in Figure 2 , and are the resonance frequencies of the tube in actuation (twist) and detection (swing) mode, respectively, and is the quality factor for the detection mode.…”
Section: Operation Principlementioning
confidence: 99%
See 4 more Smart Citations
“…Based on the analytical model of a U-shaped Coriolis mass-flow sensor presented in [ 24 ], the mass-flow sensitivity can be expressed as: where is the amplitude of the displacement in direction of the tube segment with length due to the Coriolis forces, is the amplitude of the angular displacement in the actuation mode, is the mass-flow rate, and is the total mass of the tube and the fluid inside the tube. and are the length of the tube in and direction as indicated in Figure 2 , and are the resonance frequencies of the tube in actuation (twist) and detection (swing) mode, respectively, and is the quality factor for the detection mode.…”
Section: Operation Principlementioning
confidence: 99%
“…As will be shown below, the phase difference between the motion in points (1) and ( 2) is a measure of the mass flow. Based on the analytical model of a U-shaped Coriolis mass-flow sensor presented in [24], the mass-flow sensitivity can be expressed as:…”
Section: Operation Principlementioning
confidence: 99%