2023
DOI: 10.1109/tie.2022.3170623
|View full text |Cite
|
Sign up to set email alerts
|

Modeling for Complex Modular Power Electronic Transformers Using Parallel Computing

Abstract: Cit a tio n fo r fin al p u blis h e d ve r sio n: F e n g, M o k e, G a o, C h e nxi a n g, Xu, Jia nz h o n g, Z h a o, C h e n gy o n g a n d Li, G e n 2 0 2 2. M o d eli n g for c o m pl ex m o d ul a r p o w e r el e c t r o ni c t r a n sfo r m e r s u si n g p a r all el c o m p u ti n g. IE E E Tr a n s a c tio n s o n In d u s t ri al El e c t r o nic s 1 0.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 25 publications
0
4
0
Order By: Relevance
“…By doing this, the decoupled model realizes reduced computation burden and increased simulation speed, and is easy to be used in real-time simulations. Compared to the previous work in [25], the new approach is the same accurate while being 29% faster.…”
Section: Discussionmentioning
confidence: 77%
See 1 more Smart Citation
“…By doing this, the decoupled model realizes reduced computation burden and increased simulation speed, and is easy to be used in real-time simulations. Compared to the previous work in [25], the new approach is the same accurate while being 29% faster.…”
Section: Discussionmentioning
confidence: 77%
“…In [25] , the authors proposed a modeling method for MSST using a non-decoupled equivalent circuit (EM2). Fig.…”
Section: Validation and Performancementioning
confidence: 99%
“…As seen in Figures 12-17, the open-loop transient processes are extremely rapid, taking only a few milliseconds, and they display the typical traits found in dc-dc converters. High order models can be derived for all suggested converters using state-space averaging and switching flow graph methods, whereas reduced order models can be derived using the energy factor method [18]. Due to the length constraints of the paper, it is challenging to describe in this one.…”
Section: Transient Modelling Stability Analysis and Control Strategymentioning
confidence: 99%
“…Although its accuracy is high, the disadvantage of long simulation time makes it less applied in practical applications [9]. To solve this problem, the parallel computing or the parallel simulation is proposed in [10][11][12]. However, it requires more simulation hardware resources and is more complex to apply.…”
Section: Introductionmentioning
confidence: 99%