2020
DOI: 10.1021/acs.iecr.0c04464
|View full text |Cite
|
Sign up to set email alerts
|

Modeling of Air-Gap Membrane Distillation and Comparative Study with Direct Contact Membrane Distillation

Abstract: Most of the developed models for the air-gap membrane distillation (AGMD) process are one-dimensional and rely on experimentally determined parameters. Herein, inspired by the effectiveness-number of transfer units method for the design of heat exchangers, a new approach of theoretical model is developed based on mass and heat transfer mechanisms in the AGMD process by considering the temperature variation in two dimensions. The results of our self-sustained model match well with the AGMD experimental results,… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
19
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 43 publications
(19 citation statements)
references
References 64 publications
0
19
0
Order By: Relevance
“…To reveal the effect of the feedwater flux and the concentration polarization phenomenon, the SHMD process with the photothermal or Joule-heating conversion was simulated by a finite-element method. This self-heating MD process was very similar to the standard model of the air gap membrane distillation (AGMD) . The biggest difference is that the introduction of Joule-heating and solar energy achieved the concentrated heating of the membrane, rather than directly improved the inlet temperature of the feedwater.…”
Section: Model Developmentmentioning
confidence: 83%
See 2 more Smart Citations
“…To reveal the effect of the feedwater flux and the concentration polarization phenomenon, the SHMD process with the photothermal or Joule-heating conversion was simulated by a finite-element method. This self-heating MD process was very similar to the standard model of the air gap membrane distillation (AGMD) . The biggest difference is that the introduction of Joule-heating and solar energy achieved the concentrated heating of the membrane, rather than directly improved the inlet temperature of the feedwater.…”
Section: Model Developmentmentioning
confidence: 83%
“…This self-heating MD process was very similar to the standard model of the air gap membrane distillation (AGMD). 5 The biggest difference is that the introduction of Joule-heating and solar energy achieved the concentrated heating of the membrane, rather than directly improved the inlet temperature of the feedwater.…”
Section: Model Developmentmentioning
confidence: 99%
See 1 more Smart Citation
“…The stepwise modeling approach (Figure S1) was adopted from [35] to determine the output temperatures, heat flux, and water flux of the MD module. The thermophysical properties of saline and pure water were taken from [36] (Table S3).…”
Section: Modeling Processmentioning
confidence: 99%
“…Figure S4: Percentage contributions to each impact category for the MBR-MD system. Figure S5: Percentage contributions to each impact category for the MBR-MD system scaled to the Baseline system using 11% grid energy for MD; Figure S6: Percentage contributions to each impact category for the MBR-MD system scaled to the baseline using 25% grid energy for MD [20][21][22]35,36,41,45,.…”
mentioning
confidence: 99%