Modeling of carbon fiber couch attenuation properties with a commercial treatment planning system

Abstract: The purpose of this work is to evaluate the modeling of carbon fiber couch attenuation properties with a commercial treatment planning system (TPS, Pinnacle3, v8.0d). A carbon fiber couch (Brain-Lab) was incorporated into the TPS by automatic contouring of all transverse CT slices. The couch shape and dimensions were set according to the vendor specifications. The couch composition was realized by assigning appropriate densities to the delineated contours. The couch modeling by the TPS was validated by absolut… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
70
4

Year Published

2010
2010
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 59 publications
(76 citation statements)
references
References 16 publications
2
70
4
Order By: Relevance
“…Mihaylov et al (17) detailed the implementation of couch top model and subsequent measurement verification for the ExacTrac IGRT couch top. They found that the largest beam attenuation occurred at beam entry angles of about 75° from normal incidence.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Mihaylov et al (17) detailed the implementation of couch top model and subsequent measurement verification for the ExacTrac IGRT couch top. They found that the largest beam attenuation occurred at beam entry angles of about 75° from normal incidence.…”
Section: Discussionmentioning
confidence: 99%
“…Treatment plans that do not account for a couch structure could involve significant discrepancies between the planned and actual delivered dose. Several studies have found that neglecting the couch in the dose calculation leads to mischaracterization of the delivered dose to the patient, and the impact of couch attenuation should be carefully evaluated 14 , 15 , 16 , 17 , 18 , 19 . Additionally, the recently‐published AAPM TG 176 report is available to provide guidance to physicists for modeling a couch top for accurate and realistic dose calculation (20) …”
Section: Introductionmentioning
confidence: 99%
“…( 12 , 23 ) The values quoted above were obtained with the standard Varian Clinac 6 MV beams. The high dose rate Novalis beam has a lower energy because of a modified flattening filter.…”
Section: Methodsmentioning
confidence: 99%
“…The modeling of the treatment table in Pinnacle was recently reported by Mihaylov et al ( 23 ) The table has a non‐homogeneous structure and its full representation requires a number of contours. ( 23 ) Pinnacle currently does not have a built‐in facility to include the treatment table in the plan, as described for another TPS.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation