2020
DOI: 10.1016/j.epsr.2020.106506
|View full text |Cite
|
Sign up to set email alerts
|

Modelling and improvement of open-UPQC performance in voltage sag compensation by contribution of shunt units

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 21 publications
(5 citation statements)
references
References 25 publications
0
5
0
Order By: Relevance
“…In ref. [16], a hybrid active power filter (APF) was developed to improve PQ. The adaptive ANFIS approach was employed to evaluate the PQ performance of the UPQC scheme.…”
Section: Related Work In the Literaturementioning
confidence: 99%
See 1 more Smart Citation
“…In ref. [16], a hybrid active power filter (APF) was developed to improve PQ. The adaptive ANFIS approach was employed to evaluate the PQ performance of the UPQC scheme.…”
Section: Related Work In the Literaturementioning
confidence: 99%
“…The literature mentioned above primarily focuses on PQ issues in a single microgrid operating in grid-connected mode. However, these techniques have limitations, such as complex design, poor reliability [12], the need for improvement [13,15,16], complex structure [14], inadequate performance due to unstable voltage and current supply [17,18,20], and high cost [19,21]. To address these problems and enhance system performance in the distribution system, integration with Flexible AC Transmission Systems (FACTS) is proposed.…”
Section: Related Work In the Literaturementioning
confidence: 99%
“…Power quality disturbances including voltage sag/swell, current harmonics, unbalanced load conditions, and varying solar irradiation were successfully eliminated using the proposed study but as discussed in previous studies another controller is required for the PV system operation and to maintain continuous operation of the distribution system. Ref [90] presents backward/forward sweep load flow control method linked with a UPQC-O to improve the quality of power in a distribution system. However, this study only focused on an IEEE 69-bus system and an Iranian 95-bus system.…”
Section: Open Upqc (Upqc-o)mentioning
confidence: 99%
“…For example, References 1–9 improved the power and speed of voltage sag compensation by changing the control algorithm or unit structure of power electronic mitigation equipment such as DVR and Static Synchronous Compensator (STATCOM). References 10 and 11 mitigated the voltage sag by unified power quality conditioner (UPQC) and open unified power quality conditioner (OUPQC). By improving the internal space vector pulse width modulation (SVPWM) algorithm in the UPQC model, it can detect voltage sag better and has better voltage tracking performance.…”
Section: Introductionmentioning
confidence: 99%