2006
DOI: 10.1016/j.pss.2006.05.013
|View full text |Cite
|
Sign up to set email alerts
|

Modelling CDA mass spectra

Abstract: We present the initial results from a simulation of ion behaviour within Cassini's cosmic dust analyser (CDA) instrument, using an inhouse ion dynamics code. This work is to enable and enhance the detailed interpretation of dust impact ionisation mass spectra returned from the Saturnian system. Early work has already provided insights into the properties of the impact plasma in both low-and highvelocity impacts. We find that the isotropic emission of ions from the impact plasma successfully reproduces features… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

2006
2006
2023
2023

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 13 publications
(4 citation statements)
references
References 10 publications
0
4
0
Order By: Relevance
“…The ions created by impact ionization in the impact speed regime considered here (4 – 18 km/s) are almost exclusively singly charged. Unfortunately, the TOF is also influenced by the broad distribution of initial ion velocities, slightly varying flight paths, and plasma shielding effects 32 . For that reason species with identical mass are distributed over a range of sampling points and the mass resolution drops below integer values usually around 25 - 30u.…”
Section: Methodsmentioning
confidence: 99%
“…The ions created by impact ionization in the impact speed regime considered here (4 – 18 km/s) are almost exclusively singly charged. Unfortunately, the TOF is also influenced by the broad distribution of initial ion velocities, slightly varying flight paths, and plasma shielding effects 32 . For that reason species with identical mass are distributed over a range of sampling points and the mass resolution drops below integer values usually around 25 - 30u.…”
Section: Methodsmentioning
confidence: 99%
“…The ions created by impact ionization in the impact speed regime considered here (roughly 10 km s –1 ) are almost exclusively singly charged. Unfortunately, ToF is also influenced by the broad distribution of initial ion velocities, slightly varying flight paths and plasma-shielding effects 40 . For that reason, species of identical mass are distributed over a range of sampling points and the mass resolution drops below integer values, usually at 20–30 u and above.…”
Section: Methodsmentioning
confidence: 99%
“…The trajectory of a ‘just detected’ ion is indicated, with the inset diagram showing the ion behaviour within the acceleration region due to non‐zero initial ion energy. Taken from Hillier et al (2006).…”
Section: Introductionmentioning
confidence: 99%
“…Conversion of the QM spectra from time to mass space is, in principle, simple (arrival time being proportional to the square root of the ion mass). In reality this process is complicated by the ions' initial velocity distribution, instrument geometry, plasma shielding effects and unknown precise impact times, which can broaden and shift peaks making calibration of spectra non‐trivial (Hillier et al 2006). The dominant uncertainty in determining the exact impact time (and hence the ‘zero‐point’ of the mass scale) arises from the instrument triggering method.…”
Section: Introductionmentioning
confidence: 99%