1995
DOI: 10.1080/01919519508547344
|View full text |Cite
|
Sign up to set email alerts
|

Modelling Industrial Wastewater Ozonation In Bubble Contactors. 1. Rate Coefficient Determination

Abstract: A study of the ozonation of distillery and tomato wastewaters was carried out in a small bubble contactor in order to obtain kinetic data for scaling-up. Thus, several parameters, such as chemical oxygen demand (COD), 254 nm absorbance (AJJ,) and organic carbon content (OC), were followed during ozonation at different experimental conditions.For distillery wastewaters all parameters investigated have the highest decreases during the first minutes of ozonation, A^ showing the highest disappearance rates. Thus,… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
30
0
1

Year Published

2002
2002
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 33 publications
(33 citation statements)
references
References 22 publications
2
30
0
1
Order By: Relevance
“…Moreover, the initial concentration of melanoidins in the liquid bulk (3.4 × 10 −3 mol L −1 ) was 100 times greater than the ozone equilibrium concentration ((2.5 × 10 −5 -4 × 10 −5 mol O 3 L −1 ), so it can be considered that the reaction does not cause any significant depletion of colorants through the liquid film. This fact allows us to assume the regime to be fast of pseudo-first-order [17,18]. The kinetic regime can be corroborated determining the reaction factor (E).…”
Section: Kinetic Rate Constantmentioning
confidence: 89%
“…Moreover, the initial concentration of melanoidins in the liquid bulk (3.4 × 10 −3 mol L −1 ) was 100 times greater than the ozone equilibrium concentration ((2.5 × 10 −5 -4 × 10 −5 mol O 3 L −1 ), so it can be considered that the reaction does not cause any significant depletion of colorants through the liquid film. This fact allows us to assume the regime to be fast of pseudo-first-order [17,18]. The kinetic regime can be corroborated determining the reaction factor (E).…”
Section: Kinetic Rate Constantmentioning
confidence: 89%
“…In an acid medium, the initial assumption that, by virtue of the low concentration of free radicals formed, the principal reaction mechanism must be molecular ozonolysis, allows one to neglect the second term in eqn (3), so k app ≈ k O 3 [O 3 ]. Taking into account the solubility of ozone in vinasse, 44 as well as its concentration in the reactor exit gases, the average concentration of dissolved ozone in the second segment can be estimated to be ca 5 g m −3 . Therefore, the kinetic constant will be k O 3 ≈ 1.…”
Section: Discussionmentioning
confidence: 99%
“…The mass transport is at steady state within this film and, therefore, there is no accumulation of mass. Thus, the mass balances for ozone, compound A, which dissolves and reacts with a solute B (A + ν B → P) within the film are given by equations [1] and [2]. These equations are combined with four boundary conditions given by [3] and [4].…”
Section: Classical Approach Of the Film Modelmentioning
confidence: 99%
“…Hoigné and Bader (1983) have published an extensive compilation of kinetic data obtained from systems where the reaction occurs within the bulk liquid. Beltran et al (1992Beltran et al ( , 1995Beltran et al ( , 1998 have determined the kinetic rate constant of various fast reactions by assuming a pseudo first order irreversible gas liquid reaction that takes place between ozone and the organic compound. In these studies, the reaction is assumed to occur in the liquid film, which simplifies the rate constant calculations.…”
Section: Introductionmentioning
confidence: 99%