2016
DOI: 10.1088/0029-5515/56/6/066001
|View full text |Cite
|
Sign up to set email alerts
|

Modelling of 3D fields due to ferritic inserts and test blanket modules in toroidal geometry at ITER

Abstract: Computations in toroidal geometry are systematically performed for the plasma response to 3D magnetic perturbations, produced by ferritic inserts (FIs) and test blanket modules (TBMs), for four ITER plasma scenarios: the 15MA baseline, the 12.5MA hybrid, the 9MA steady state, and the 7.5MA half-field Helium plasma. Due to broad toroidal spectrum of the FI and TBM fields, the plasma response for all the n=1-6 field components are computed and compared. The plasma response is found to be weak for the high-n (n >… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
13
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
8

Relationship

4
4

Authors

Journals

citations
Cited by 10 publications
(14 citation statements)
references
References 35 publications
1
13
0
Order By: Relevance
“…Two different MHD codes were used to calculate the plasma response: MARS-F [15,16] is a one-fluid, linear (each n solved independently) code solving the full resistive MHD equations in toroidal geometry. JOREK [4] is a two-fluid, non-linear code solving the reduced MHD equations in toroidal geometry which (unlike for MARS-F) includes the divertor and X-point.…”
Section: Overview Of the Models Used To Evaluate The Plasma Response ...mentioning
confidence: 99%
See 1 more Smart Citation
“…Two different MHD codes were used to calculate the plasma response: MARS-F [15,16] is a one-fluid, linear (each n solved independently) code solving the full resistive MHD equations in toroidal geometry. JOREK [4] is a two-fluid, non-linear code solving the reduced MHD equations in toroidal geometry which (unlike for MARS-F) includes the divertor and X-point.…”
Section: Overview Of the Models Used To Evaluate The Plasma Response ...mentioning
confidence: 99%
“…For MARS-F the procedure is similar with the exception that only magnetic field is used (not vector potential) and Fourier decomposition is done also in the poloidal direction. The MARS-F calculations are described in detail in [18].…”
Section: Overview Of the Models Used To Evaluate The Plasma Response ...mentioning
confidence: 99%
“…Although previous modeling for ITER [20,52] has demonstrated a relatively weak effect of flow variation on the plasma response, as long as the flow remains sufficiently fast and the flow speed does not vary by order of magnitude, this sensitivity issue need to be checked for DEMO plasmas.…”
Section: Choice Of Coil Geometry and Coil Current Phasingmentioning
confidence: 99%
“…Note also a roughly 60 • offset between the vacuum and plasma response criteria for low-n (n = 1-3) RMP fields. The offset is somewhat smaller for the n = 4 field, indicating that the plasma response plays a less important role with higher-n RMPs [64].…”
Section: Plasma Response With Varying Elongationmentioning
confidence: 93%