2002
DOI: 10.1002/1521-3986(200201)42:1<81::aid-ctpp81>3.0.co;2-7
|View full text |Cite
|
Sign up to set email alerts
|

Modelling of the Temporal Behaviour of the Inter-Anode Current in a System of Two Coupled Electrical Discharges

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2004
2004
2015
2015

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 12 publications
(10 citation statements)
references
References 20 publications
0
10
0
Order By: Relevance
“…Many past studies on such systems have therefore relied on driving a single plasma system with an external frequency source. [5][6][7][8][9][10][11][12][13] There have been very few studies devoted to the investigation of mutual synchronization between two plasma systems except 14 where this phenomenon was studied between two double plasma devices and 15 where it was investigated in two electrical discharges. In Ref.…”
Section: Introductionmentioning
confidence: 99%
“…Many past studies on such systems have therefore relied on driving a single plasma system with an external frequency source. [5][6][7][8][9][10][11][12][13] There have been very few studies devoted to the investigation of mutual synchronization between two plasma systems except 14 where this phenomenon was studied between two double plasma devices and 15 where it was investigated in two electrical discharges. In Ref.…”
Section: Introductionmentioning
confidence: 99%
“…The various nonlinear dynamics observed in the behavior of the twin electrical discharge plasma are satisfactorily reproduced by the following model system of equations [1,6,7]:…”
Section: Results Of the Computational Modelmentioning
confidence: 94%
“…On a particular case of harmonic perturbation (with given amplitude and frequency), the possibility of modelling of the dynamics of perturbed charge structures of double layer (DL) type -as dynamics of coupled Van der Pol oscillators was demonstrated [1]. Based on the same idea now, results of a more in depth study on a perturbed discharge plasma DL are presented.…”
Section: Introductionmentioning
confidence: 99%
“…The best fitting curve gives H = 1.545 and V C = 15.5 V. This critical value of the voltage is remarkably close to the ionization potential of the working gas ͑argon͒ V ion = 15.6 V. The result is in very good agreement with the accepted situation that instability is caused by the charge structures of double layer type, generated in the neighborhood of the additional electrode. 14,19 For values of the voltage in excess of the ionization potential, the structure becomes unstable and different types of dynamics can be initiated in the discharge plasma. Although the LAM value expected for a periodic time series is 1, our computed result is only 0.965.…”
Section: Equivalence Between the Duration Of The Laminar Phase Anmentioning
confidence: 99%