2017
DOI: 10.1016/j.epsr.2017.01.037
|View full text |Cite
|
Sign up to set email alerts
|

Modelling of three-phase electric arc furnace for estimation of voltage flicker in power transmission network

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
15
0
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 35 publications
(16 citation statements)
references
References 16 publications
0
15
0
1
Order By: Relevance
“… Both sintering devices, induction furnaces and arc furnaces are heavy harmonic sources. The harmonic examination of the arc furnaces has already been done in literature well-known [10], [12], [13], [18]- [21], [23], [28]. The harmonics of an electric current assisted sintering system is to be examined in the near future by the present authors.…”
Section: The Harmful Attacksmentioning
confidence: 97%
See 2 more Smart Citations
“… Both sintering devices, induction furnaces and arc furnaces are heavy harmonic sources. The harmonic examination of the arc furnaces has already been done in literature well-known [10], [12], [13], [18]- [21], [23], [28]. The harmonics of an electric current assisted sintering system is to be examined in the near future by the present authors.…”
Section: The Harmful Attacksmentioning
confidence: 97%
“…Electric arc furnaces (EAFs) are one of the common technology used in steel industries and widely used to produce steel by melting recycled scrap steel [23], [24], [31], [45]. The EAF contributes to steelmaking by providing more than 25% of the world's total crude steel production [14].…”
Section: Arc Furnace and Its Electrical Power Circuitmentioning
confidence: 99%
See 1 more Smart Citation
“…The magnitude of voltage fluctuation is based on the length of the electric arc. These shortcomings result in the improper working of the devices, rapid aging, and reduced efficiency in transmitting and receiving sides [3]. EAF causes power quality issues due to its non-linear characteristics.…”
Section: Introductionmentioning
confidence: 99%
“…Dynamic loads always generate harmonics in the power system and reduces the performance of electrical equipment. Electric arc furnace is such type of load which causes voltage fluctuation when connected to the grid in the electrical system thereby leading to the problem of voltage flicker [5], [6]. These power quality problems results in reduction of efficiency and performance of electrical equipment.…”
Section: Introductionmentioning
confidence: 99%