2013
DOI: 10.1016/j.snb.2013.04.062
|View full text |Cite
|
Sign up to set email alerts
|

Modelling ultrasonic sensor for gas bubble profiles characterization of chemical column

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2016
2016
2020
2020

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 20 publications
(8 citation statements)
references
References 9 publications
0
8
0
Order By: Relevance
“…So far, there have been many technologies to achieve chemical sensing, including acoustic 2 , 3 , optical 4 6 , pure chemical 7 and electromagnetic 8 , 9 detection. In ultrasonic sensors, the transmitter sends a discontinuous signal to the liquid, and then the echo signal is detected to obtain information including time of flight, signal amplitude, and further determines the property of sample based on the theory of Hale 10 .…”
Section: Introductionmentioning
confidence: 99%
“…So far, there have been many technologies to achieve chemical sensing, including acoustic 2 , 3 , optical 4 6 , pure chemical 7 and electromagnetic 8 , 9 detection. In ultrasonic sensors, the transmitter sends a discontinuous signal to the liquid, and then the echo signal is detected to obtain information including time of flight, signal amplitude, and further determines the property of sample based on the theory of Hale 10 .…”
Section: Introductionmentioning
confidence: 99%
“…As shown in Figure 4, attenuation of ultrasonic waves occurs during propagation through a medium, and this procession can be described by the following equation:p=p0expfalse(αLfalse) α=1Llnpp0 where, p and p 0 are the acoustic pressure after the propagation distance L , and the initial incident acoustic pressure, respectively, and α refers to the attenuation coefficient of sound pressure. At room temperature, attenuation coefficient in water α equals 25.3 × 10 −15 f 2 , and its unit is Np/m [22]. The attenuation coefficient α is proportional to the square of the excitation frequency f .…”
Section: Working Principles and Theoretical Backgroundmentioning
confidence: 99%
“…For examples, ERT technique coupled with differential pressure measurement to [19,20], and the ECT technique coupled with the optical measurement method [16]. Ultrasonic tomography (UT) can also be used to monitor the gas holdup in bubble columns [21,22] and other types of chemical mixtures, such as liquid-liquid flow patterns [23,24]. The working principle of ultrasonic tomography (UT) is based on the interaction between the ultrasonic wave and the medium measured.…”
Section: Introductionmentioning
confidence: 99%
“…33, No. 4) in the bubble diameter, as illustrated by the computed results through sound field numerical simulation [10,23]. However, for the situation with multiple bubbles in the pipe, the ultrasonic field distribution is also complex and worth exploring.…”
Section: Simulation Of the Different Bubble Sizes And Distributionmentioning
confidence: 99%
“…The dispersed phase concentration plays an important role in the amplitude of the transmission ultrasound [8], and the ultrasonic attenuation changed with regularity when the gas flow rate increased [9]. Rahiman et al introduced a mathematical model to explain the influence of a single gas bubble on ultrasound propagation, concluding that the ultrasonic attenuation increased with increases in the bubble diameter [10]. Supardan et al reported that in a rectangular bubble column, the ultrasonic attenuation has an approximate linear relationship with gas holdup in a certain range [11].…”
Section: Introductionmentioning
confidence: 99%