2021
DOI: 10.7717/peerj.12192
|View full text |Cite
|
Sign up to set email alerts
|

Modernising tactile acuity assessment; clinimetrics of semi-automated tests and effects of age, sex and anthropometry on performance

Abstract: Background Reduced tactile acuity has been observed in several chronic pain conditions and has been proposed as a clinical indicator of somatosensory impairments related to the condition. As some interventions targeting these impairments have resulted in pain reduction, assessing tactile acuity may have significant clinical potential. While two-point discrimination threshold (TPDT) is a popular method of assessing tactile acuity, large measurement error has been observed (impeding responsiveness… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 85 publications
0
2
0
Order By: Relevance
“…The determination of single 2PD threshold was according to a previously validated protocol [24]. In brief, 4 runs (2 ascending and 2 descending) were performed, however, the first ascending series was based on 5mm steps while the remaining series used on 2mm increments (see [24] for details). Participants reported their sensations using a 2-alternative forced-choice paradigm (1 vs 2 stimuli perceived).…”
Section: Study Structure and Designmentioning
confidence: 99%
See 1 more Smart Citation
“…The determination of single 2PD threshold was according to a previously validated protocol [24]. In brief, 4 runs (2 ascending and 2 descending) were performed, however, the first ascending series was based on 5mm steps while the remaining series used on 2mm increments (see [24] for details). Participants reported their sensations using a 2-alternative forced-choice paradigm (1 vs 2 stimuli perceived).…”
Section: Study Structure and Designmentioning
confidence: 99%
“…The 2PD was determined along the horizontal as well vertical axis using a plastic caliper (CarolinaÒ Biological Supply Company, Burlington, NC). The determination of single 2PD threshold was according to a previously validated protocol [24]. In brief, 4 runs (2 ascending and 2 descending) were performed, however, the first ascending series was based on 5mm steps while the remaining series used on 2mm increments (see [24] for details).…”
Section: Study Structure and Designmentioning
confidence: 99%