2017
DOI: 10.1051/e3sconf/20172200083
|View full text |Cite
|
Sign up to set email alerts
|

Modification of Rhodamine WT tracer tests procedure in activated sludge reactors

Abstract: Abstract.One of the tracers recommended for use in wastewater treatment plants and natural waters is Rhodamine WT, which is a fluorescent dye, allowing to work at low concentrations, but may be susceptible to sorption to activated sludge flocs and chemical quenching of fluorescence by dissolved water constituents. Additionally raw sewage may contain other natural materials or pollutants exhibiting limited fluorescent properties, which are responsible for background fluorescence interference. This paper present… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 12 publications
0
2
0
Order By: Relevance
“…The intensity of mixing leads to enhanced mass exchange in the AT, hence directly influencing the concentration of residual polluting matter in the effluent. The knowledge of actual reactor MRT can prevent incomplete biochemical reactions in ASP and help in growth of desirable microorganisms [14,23,33]. With the optimal combination of operating parameters, optimized ASP performance can be achieved that result in minimum BOD and COD of the treated effluent [34].…”
Section: Effects Of Varying Operational Parameters On Biological Treamentioning
confidence: 99%
See 1 more Smart Citation
“…The intensity of mixing leads to enhanced mass exchange in the AT, hence directly influencing the concentration of residual polluting matter in the effluent. The knowledge of actual reactor MRT can prevent incomplete biochemical reactions in ASP and help in growth of desirable microorganisms [14,23,33]. With the optimal combination of operating parameters, optimized ASP performance can be achieved that result in minimum BOD and COD of the treated effluent [34].…”
Section: Effects Of Varying Operational Parameters On Biological Treamentioning
confidence: 99%
“…However, the ASP involves several combinations of complex physical, biological and chemical processes [19], conventional RTD models as tank-in-series (TIS), axial dispersion model reported in the literature fail to provide a comprehensive view of the performance of ASP [20,21]. Compartment models are a combination of discrete reactors (CSTR and PFR) connected in a different configuration to provide a global approach to view of the hydrodynamic performance of the ASP and provide critical information for optimizing the plant operation [22][23][24].…”
Section: Introductionmentioning
confidence: 99%