2021
DOI: 10.1103/physrevmaterials.5.124601
|View full text |Cite
|
Sign up to set email alerts
|

Modified band alignment method to obtain hybrid functional accuracy from standard DFT: Application to defects in highly mismatched III-V:Bi alloys

Abstract: This paper provides an accurate theoretical defect energy database for pure and Bi-containing 111-V (111-V:Bi) materials and investigates efficient methods for high-throughput defect calculations based on corrections of results obtained with local and semi-local functionals. Point defects as well as nearest-neighbor and second-nearest-neighbor pair defects were investigated in charge states ranging from -5 to 5. Ga-V:Bi systems (GaP:Bi, GaAs:Bi, and GaSb:Bi) were thoroughly investigated with significantly slow… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(5 citation statements)
references
References 81 publications
0
5
0
Order By: Relevance
“…Note that we find errors are similar for lower and higher band gap materials, making the errors particularly problematic for systems with low band gaps. In addition, it is worth noting that for some defects and charge states, an LDA/GGA approach may incorrectly capture localization effects 27,38 , which is not corrected for in any band alignment-like method, including MBA 26 . These cases are difficult to unambiguously identify in a high-throughput approach, and are therefore included in this model as well, influencing the statistics.…”
Section: Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…Note that we find errors are similar for lower and higher band gap materials, making the errors particularly problematic for systems with low band gaps. In addition, it is worth noting that for some defects and charge states, an LDA/GGA approach may incorrectly capture localization effects 27,38 , which is not corrected for in any band alignment-like method, including MBA 26 . These cases are difficult to unambiguously identify in a high-throughput approach, and are therefore included in this model as well, influencing the statistics.…”
Section: Resultsmentioning
confidence: 99%
“…This choice can lead to the relaxation algorithm failing to find some local minima 33 but was made to allow efficiency in the high-throughput calculations that enable this study. More details of the DFT calculations can be found in Mannodi-Kanakkithodi et al 25 and Polak et al 26 The LDA/GGA results from these studies were corrected with the MBA scheme, which is described in details in Ref. 26 .…”
Section: Datasets and Methodsmentioning
confidence: 99%
See 3 more Smart Citations