Modified Curved Aspiration Cannulas and End-Gripping Forceps for 25-Gauge Vitrectomy on Highly Myopic Eyes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0
1

Year Published

2017
2017
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(12 citation statements)
references
References 5 publications
0
11
0
1
Order By: Relevance
“…Considering that eyes with extremely high myopia can frequently exceed 30 mm in the axial length, surgical instrumentation, such as vitreous forceps, must be evaluated accurately during PPV. To overcome the inability to reach the retinal surface, surgeons can verticalize the instruments and carefully apply a pressure on the sclera wall in order to temporarily reduce the axial length of the globe [ 105 ]. However, these maneuvers are not free from complications, such as limited visibility due to erroneous contact and dislocation of the viewing system, corneal folds and impaired surgeon maneuverability which result in a longer operation time and challenging surgical procedures [ 106 ].…”
Section: Surgical Techniquesmentioning
confidence: 99%
“…Considering that eyes with extremely high myopia can frequently exceed 30 mm in the axial length, surgical instrumentation, such as vitreous forceps, must be evaluated accurately during PPV. To overcome the inability to reach the retinal surface, surgeons can verticalize the instruments and carefully apply a pressure on the sclera wall in order to temporarily reduce the axial length of the globe [ 105 ]. However, these maneuvers are not free from complications, such as limited visibility due to erroneous contact and dislocation of the viewing system, corneal folds and impaired surgeon maneuverability which result in a longer operation time and challenging surgical procedures [ 106 ].…”
Section: Surgical Techniquesmentioning
confidence: 99%
“…fluid or perfluorocarbon liquid removal, ERM and inner limiting membrane [ILM] peeling) may be severely impaired [ 5 ]. The surgeon has to verticalize the instruments and apply pressure on the sclera in order to transitorily shorten the axial length of the eyeball [ 4 , 6 ]. All these elements result in reduced surgeon’s maneuverability, erroneous contact with the viewing system, limited visibility because of corneal folds, longer and more challenging surgical procedures [ 4 , 6 ].…”
Section: Introductionmentioning
confidence: 99%
“…The surgeon has to verticalize the instruments and apply pressure on the sclera in order to transitorily shorten the axial length of the eyeball [ 4 , 6 ]. All these elements result in reduced surgeon’s maneuverability, erroneous contact with the viewing system, limited visibility because of corneal folds, longer and more challenging surgical procedures [ 4 , 6 ]. Some practical tips can be employed to overcome these issues.…”