2019
DOI: 10.1155/2019/2524583
|View full text |Cite
|
Sign up to set email alerts
|

Modified Small-Volume Jet Nebulizer Based on CFD Simulation and Its Clinical Outcomes in Small Asthmatic Children

Abstract: The small-volume jet nebulizer (SVJN) is an aerosol device used to treat respiratory illnesses. Major problems for aerosol treatment in small children include the penetration of particles to the lower lungs due to irregular and small volume of a child patient’s breath while the nebulizers used are the same models intended for adults. This adult SVJN produces a huge number of particles at a higher speed than small children can intake. To solve this problem, computational fluid dynamics (CFD) was used to redesig… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8
1

Relationship

4
5

Authors

Journals

citations
Cited by 16 publications
(8 citation statements)
references
References 14 publications
0
8
0
Order By: Relevance
“…In simulation, the particles would be simulated by releasing them from the products' surfaces to simulate the particle trace using DPM in a transient state as explained in 2.2. As for other necessary settings, we used the same ones that were successful in the medicine particle trace simulation in the small-volume jet nebulizer to seek the optimal design and conditions for inhaling medicine for child asthmatic patients [30]. In the second section, to find suitable conditions to use the UCT, we used the same settings as mentioned above, but simulated by using water flow rates when the inlet were 7.5, 10, and 15 L/min.…”
Section: Cfd Settingmentioning
confidence: 99%
“…In simulation, the particles would be simulated by releasing them from the products' surfaces to simulate the particle trace using DPM in a transient state as explained in 2.2. As for other necessary settings, we used the same ones that were successful in the medicine particle trace simulation in the small-volume jet nebulizer to seek the optimal design and conditions for inhaling medicine for child asthmatic patients [30]. In the second section, to find suitable conditions to use the UCT, we used the same settings as mentioned above, but simulated by using water flow rates when the inlet were 7.5, 10, and 15 L/min.…”
Section: Cfd Settingmentioning
confidence: 99%
“…Convergent criterion was set as 10 -4 . The turbulence model was shear stress relevant to industrial and medical applications [10][11]. This turbulence model combined the advantages of both k − ω and k − ε turbulence models together, thus enabling us to simulate the fluid's flow behavior in the inner area of the boundary layer accurately, which is the k − ω's uniqueness.…”
Section: Boundary Conditionsmentioning
confidence: 99%
“…For the turbulence equation, the shear stress transport (SST) k-ω turbulence model was chosen, as in [1,[20][21][22][23]. The SST k-ω equation can be written as…”
Section: Aerodynamicsmentioning
confidence: 99%