Modified STATCOM control strategy for fault ride-through capability enhancement of grid-connected PV/wind hybrid power system during voltage sag

Abstract: This paper proposes the employment of Static Synchronous Compensator (STATCOM) in reactive power compensation to enhance the Fault Ride-Through (FRT) capability and improve the dynamic performance of a grid-connected PV/wind hybrid power system during the transient grid disturbances. The hybrid power system consisting of 9 MW Doubly Fed Induction Generator (DFIG)-based wind farm and 1 MW PV station is integrated with 100 MVAR STATCOM at the Point of Common Coupling (PCC) bus. The dynamic performance of the PV/… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
19
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 39 publications
(19 citation statements)
references
References 45 publications
0
19
0
Order By: Relevance
“…In addition, low voltage at the PCC reduces the capacity of the GSC to transfer active power to the grid. is leads to excess power in the DC link capacitor, resulting in increased DC link voltage [25,28].…”
Section: E Mathematical Modeling Of Dfigmentioning
confidence: 99%
See 2 more Smart Citations
“…In addition, low voltage at the PCC reduces the capacity of the GSC to transfer active power to the grid. is leads to excess power in the DC link capacitor, resulting in increased DC link voltage [25,28].…”
Section: E Mathematical Modeling Of Dfigmentioning
confidence: 99%
“…us, the fundamental component of V st is proportional to V dc . VSI controller operation starts with a measurement system which obtains DC capacitor voltage V dc , STATCOM reactive current I abc , and bus line voltage V g,abc [28,35], as shown in Figure 5.…”
Section: Statcom Operation and Controlmentioning
confidence: 99%
See 1 more Smart Citation
“…For a hybrid power system in which PV and wind plants are integrated through a common DC bus, a PI‐STATCOM can be employed to improve the voltage profile of the load bus 80 . Hamdan et al 81 proposed a modified STATCOM controller to increase the dynamic performance and lower the voltage dips. The authors of References 82 and 83 adopt an eigen‐structure assignment approach for enhancing system stability.…”
Section: Control Of Statcoms In Wind/pv Integrated Power Systemsmentioning
confidence: 99%
“…The study concerned to improve the system dynamic performance in the post-fault duration and the simulation results confirmed the superior impact of the STATCOM compared with the Static Var Compesnasator (SVC) when subjected to 3LG fault at different locations in the grid. In [15], the paper presented the utilization of STATCOM in reactive power compensation to enhance the dynamic behavior for a grid-tied hybrid PV/wind energy system under the fault events. The results validated the effectiveness of the STATCOM controller in improving the transient stability compared with the conventional FRT control scheme when a severe three-phase grid voltage sag occurs.…”
Section: Iintroductionmentioning
confidence: 99%