2022
DOI: 10.1109/tpel.2021.3092773
|View full text |Cite
|
Sign up to set email alerts
|

Modified Z-Source DC Circuit Breaker With Enhanced Performance During Commissioning and Reclosing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 33 publications
(4 citation statements)
references
References 22 publications
0
4
0
Order By: Relevance
“…By adding a semi-controlled device in the breaker, manual tripping is initiated, and an artificial fault current with a large magnitude can be induced comparatively with less loss than an SCR in the conduction path. A brief comparison of bidirectional SZSCB proposed in [24,62] with the new design presented in [63] states that, while commutation of thyristor, a spike in current may appear due to reverse recovery. With this current spike in input, the coordination of the circuit breaker might be affected.…”
Section: ) Series Z -Source Circuit Breakermentioning
confidence: 99%
See 1 more Smart Citation
“…By adding a semi-controlled device in the breaker, manual tripping is initiated, and an artificial fault current with a large magnitude can be induced comparatively with less loss than an SCR in the conduction path. A brief comparison of bidirectional SZSCB proposed in [24,62] with the new design presented in [63] states that, while commutation of thyristor, a spike in current may appear due to reverse recovery. With this current spike in input, the coordination of the circuit breaker might be affected.…”
Section: ) Series Z -Source Circuit Breakermentioning
confidence: 99%
“…OF IMPEDANCE BASED CIRCUIT BREAKER TOPOLOGIES[63,74,77] This article has been accepted for publication in IEEE Access. This is the author's version which has not been fully edited and content may change prior to final publication.…”
mentioning
confidence: 99%
“…In the Ref. [87], the issues suffered by ZSCBs are presented: (1) a high starting current in the main thyristor SCR. (2) unwanted power flow in the load during the commissioning and reclosing of ZSCBs.…”
Section: Z-source: the New Generation Of Sscbsmentioning
confidence: 99%
“…In Z source-based DCCB [24], [25], current commutation is done using the impedance network; however, it has the drawback of automatic actuation if there is even a slight load variation. The issues of high starting current and unwanted power flow are rectified using a parallel snubber branch which dissipates the trapped energy in the inductor [26]; nevertheless, in the Z source, load current flows through the semiconductor device, so conduction losses are significant [27]. Lazzari et al [28] implemented a Low Voltage hybrid DCCB, which addresses the problem of twice the fault current in the circuit elements.…”
Section: Introductionmentioning
confidence: 99%