2015 IEEE Eindhoven PowerTech 2015
DOI: 10.1109/ptc.2015.7232324
|View full text |Cite
|
Sign up to set email alerts
|

Modular modelling of combined AC and DC systems in dynamic simulations

Abstract: Abstract-A formulation is proposed in which an AC-DC system is modeled as a combination of AC grids, DC grids, injectors, AC two-ports and AC/DC converters, respectively. This modular modelling facilitates the dynamic simulation of future complex AC/DC systems. Furthermore, it can be exploited by the solver, which performs less operations on components with lower dynamic activity, and offers parallel processing of the time simulation. This approach is illustrated on a test system in which a multi-terminal DC g… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2016
2016
2019
2019

Publication Types

Select...
3
2

Relationship

4
1

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 8 publications
0
5
0
Order By: Relevance
“…The weighting factor v (see Eq. (5) All time simulations were performed in phasor mode with RAMSES, a time simulation software developed at the University of Liège [26], using the techniques described in [27]. A total of five scenarios are demonstrated.…”
Section: Test System and Modelingmentioning
confidence: 99%
“…The weighting factor v (see Eq. (5) All time simulations were performed in phasor mode with RAMSES, a time simulation software developed at the University of Liège [26], using the techniques described in [27]. A total of five scenarios are demonstrated.…”
Section: Test System and Modelingmentioning
confidence: 99%
“…The behaviour of the controller has been tested with off-line dynamic simulations in Ramses, a FORTRAN-based dynamic simulation tool developed at University of Liege, which is mandatory for the designed real-time solver [21]. Before moving to the mock-up low-scale DC grid, some steps are required to validate the controller in the tools used by L2EP laboratory, as shown in Fig.…”
Section: Validation Of the Mpc Controller For High Voltage Mtdc Gridmentioning
confidence: 99%
“…All dynamic simulations were performed with RAMSES, a time simulation software developed at the Univ. of Liège [16], using the techniques described in [17]. Following the fault, the VSC voltage drops below the threshold of 0.9 pu, as shown in Fig.…”
Section: ) Case 1 -Tripping Of Short Reactance With Faultmentioning
confidence: 99%