2019
DOI: 10.1109/tia.2019.2938739
|View full text |Cite
|
Sign up to set email alerts
|

Modulation Effects in an Inverter Fed Nine-Phase Induction Motor Drive

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(6 citation statements)
references
References 36 publications
0
6
0
Order By: Relevance
“…Moreover, the hexagonal voltage space vectors formed by Group‐II and Group‐III are phase‐shifted by 40 0 and 80 0 , respectively, with respect to that of produced by Group‐I as presented in Figure 2A. Similarly, a total of 2 9 = 512 combinations are possible for the switching vector of a nine‐phase group which are distributed over multiple locations as presented in References 19 and 21 The resultant switching vector for a nine‐phase group is as given in Equation (1). Vr=()VX1ej00+VY1ej1200+VZ1ej2400+()VX2ej400+VY2ej1600+VZ2ej2800+()VX3ej800+VY3ej2000+VZ3ej3200 …”
Section: Octadecagonal Svpwm Controlled Nine‐phase Imdmentioning
confidence: 96%
See 1 more Smart Citation
“…Moreover, the hexagonal voltage space vectors formed by Group‐II and Group‐III are phase‐shifted by 40 0 and 80 0 , respectively, with respect to that of produced by Group‐I as presented in Figure 2A. Similarly, a total of 2 9 = 512 combinations are possible for the switching vector of a nine‐phase group which are distributed over multiple locations as presented in References 19 and 21 The resultant switching vector for a nine‐phase group is as given in Equation (1). Vr=()VX1ej00+VY1ej1200+VZ1ej2400+()VX2ej400+VY2ej1600+VZ2ej2800+()VX3ej800+VY3ej2000+VZ3ej3200 …”
Section: Octadecagonal Svpwm Controlled Nine‐phase Imdmentioning
confidence: 96%
“…The total nine‐phase windings are re‐organized as 3 three‐phase groups namely: Group‐I ( X 1 , Y 1 , Z 1 ), Group‐II ( X 2 , Y 2 , Z 2 ), and Group‐III ( X 3 , Y 3 , Z 3 ), where the windings are phase shifted by 120 0 in each group. In addition, the performance of nine‐phase IMD with and without isolated neutrals is given in References 16,18,19 and it is found that the modeling of three isolated neutrals N 1 , N 2 , N 3 eliminates the flow of triplen harmonic currents through the phase windings.…”
Section: Octadecagonal Svpwm Controlled Nine‐phase Imdmentioning
confidence: 99%
“…Introduces another variable S 11 , S 21 and S 31 which taking 1 if the switch k i1 is closed or −1 if the switch opened ( Fig. 3) [16][17][18][19][20][21]…”
Section: Modeling and Control Of Studied System 31 Modeling Of Grid mentioning
confidence: 99%
“…However in some cases, some degree of performance degradation is accepted. In these cases, a suitable reconfiguration might be enough to assure the minimum required performance [1,10,21]. After fault detection and isolation, a reconfiguration is necessary.…”
Section: Fault Tolerant Systemmentioning
confidence: 99%
“…Thus, a requirement is there with respect to changing the number of poles in the IMD in running condition without having any mechanical reconfiguration. Various solutions are given in literature for the necessary sophisticated control techniques [2,[4][5][6][7][8]10,[12][13][14][15]17] to achieve the same. Among various control techniques available in literature, the electronic pole changing (EPC) technique is most promising solution [2,4,[5][6][7][8].…”
Section: Introductionmentioning
confidence: 99%