2009 IEEE International Electric Machines and Drives Conference 2009
DOI: 10.1109/iemdc.2009.5075457
|View full text |Cite
|
Sign up to set email alerts
|

Modulation strategies for direct-link drive for open-end winding AC machines

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
19
0
3

Year Published

2009
2009
2016
2016

Publication Types

Select...
3
2

Relationship

1
4

Authors

Journals

citations
Cited by 28 publications
(22 citation statements)
references
References 10 publications
0
19
0
3
Order By: Relevance
“…It can be found that there are two different but totally equivalent sets of active vectors which do not produce zero sequence voltages [11]; these sets are given in Table 2 A representation of the locus formed by the space vectors producing null is shown in Fig. 7 where it can be seen that the hexagon is divided into six sectors and among the eight null vectors available, only six are finally used (three null vectors per set) in order to reduce the commutations in a period [12]. Moreover the null vectors should be mapped depending on the sector information [12]; the mapping is shown in Table 3.…”
Section: Modulation For the Output Stages Of The Imcmentioning
confidence: 99%
See 3 more Smart Citations
“…It can be found that there are two different but totally equivalent sets of active vectors which do not produce zero sequence voltages [11]; these sets are given in Table 2 A representation of the locus formed by the space vectors producing null is shown in Fig. 7 where it can be seen that the hexagon is divided into six sectors and among the eight null vectors available, only six are finally used (three null vectors per set) in order to reduce the commutations in a period [12]. Moreover the null vectors should be mapped depending on the sector information [12]; the mapping is shown in Table 3.…”
Section: Modulation For the Output Stages Of The Imcmentioning
confidence: 99%
“…7 where it can be seen that the hexagon is divided into six sectors and among the eight null vectors available, only six are finally used (three null vectors per set) in order to reduce the commutations in a period [12]. Moreover the null vectors should be mapped depending on the sector information [12]; the mapping is shown in Table 3. …”
Section: Modulation For the Output Stages Of The Imcmentioning
confidence: 99%
See 2 more Smart Citations
“…Both of the techniques use large number of switches which increases the switching loss, cost and volume of the system. A reduced switch count matrix converter driven open-ended load topology is proposed which is quite simple from both design and operation perspective [21].…”
Section: Introductionmentioning
confidence: 99%