Abstract:This study analyses moisture dry-out from a steel-faced insulated sandwich panel by forced convection. Moisture convection performance was studied by laboratory tests and simulation. Two test walls with the lower parts close to the free water level were studied in a laboratory with and without convection. In addition, a real-scale wall was built to south orientate direction. Measurements were also used for simulation model calibration. The hygrothermal simulations were performed with the simulation tool Delphi… Show more
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.