1988
DOI: 10.1111/j.1365-2621.1988.tb13566.x
|View full text |Cite
|
Sign up to set email alerts
|

Moisture Sorption Method for Hygroscopic Samples Using a Modified Proximity Equilibration Cell

Abstract: The study was undertaken to develop a suitable design to accommodate liquefying hygroscopic samples in the Proximity Equilibrium Cell (PEC) for equilibration to desired water activity. The system suggested has overcome the limitation of the earlier reported methods using PEC and is found to be rapid compared to other gravimetric methods used for hygroscopic materials.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2000
2000
2020
2020

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 4 publications
0
5
0
Order By: Relevance
“…A total of 32 loads were used for each starch sample with eight duplicated loads each for sorption and desorption measurements. After five to six days of equilibration (Chinachoti and Steinberg 1985; Kanade and Pai 1988), the moisture contents of samples were measured by oven-drying at 130°C (AACC 2000). The weight gained or lost by filter paper at each a w was measured in a separate experiment.…”
Section: Water Vapor Sorption and Desorption Of Rsmentioning
confidence: 99%
See 1 more Smart Citation
“…A total of 32 loads were used for each starch sample with eight duplicated loads each for sorption and desorption measurements. After five to six days of equilibration (Chinachoti and Steinberg 1985; Kanade and Pai 1988), the moisture contents of samples were measured by oven-drying at 130°C (AACC 2000). The weight gained or lost by filter paper at each a w was measured in a separate experiment.…”
Section: Water Vapor Sorption and Desorption Of Rsmentioning
confidence: 99%
“…The use of a proximity equilibration cell (PEC) to rapidly equilibrate a sample to an atmosphere of known relative humidity was developed by Lang et al (1981). The PEC method has advantages over other methods (Chinachoti and Steinberg 1985;Kanade and Pai 1988) in precision, simplicity, and rapid measurement.…”
mentioning
confidence: 99%
“…Water uptake of solid polyacid samples was measured gravimetrically at fixed relative humidities and temperatures by using a home-built controlled humidity chamber inspired from the literature. , It was made from a small commercial borosilicate glass desiccator with a closely attached lid (see Scheme ), on whose bottom a small cylindrical vessel ( A ) containing a saturated aqueous solution of a specific inorganic salt was positioned. An excess of inorganic salt was added to the saturated solution to ensure that saturation was maintained in the whole range of investigated temperatures.…”
Section: Methodsmentioning
confidence: 99%
“…Experiments were conducted under controlled conditions of relative humidity and temperature. Proximity equilibration cells (PECs) have been used by many researchers , to study sorption isotherms. Six saturated salt solutions were used to obtain different relative humidities .…”
Section: Experimental Setup and Proceduresmentioning
confidence: 99%