Molecular contamination testing with continuous-wave laser radiation at 1064 nm: de-risking activity for the LISA space mission

Abstract: This paper presents a set of developed tools and methods for the stray light analysis of the Compact Gas Imager, a new sensor concept to capture images of gases, featuring a peculiar optical concept. The disruptive optical concept requires an adaptation of existing tools and the development of new technics for accurate stray light analysis. The described approach consists in deriving the stray light requirements from the requirements for the gas concentration by use of theoretical models and a set of approxima… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 10 publications
0
2
0
Order By: Relevance
“…Considering this, LIC seems to be less of a concern for the LISA mission (1064nm, continuous-wave (cw), 150W/cm 2 ). Nonetheless, LIC did occur in the near-infrared (NIR) in multiple experimental studies [9,10,11] and the long mission duration, the financial and scientific significance of the mission, the lack of studies regarding the impact of potentially small deposits on the wavefront [12] and the estimation of the LISA working group that even a 2 nm deposit will start affecting the detection performance adversely (see Figure 1), lead to the conclusion that a comprehensive de-risking activity is crucial.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Considering this, LIC seems to be less of a concern for the LISA mission (1064nm, continuous-wave (cw), 150W/cm 2 ). Nonetheless, LIC did occur in the near-infrared (NIR) in multiple experimental studies [9,10,11] and the long mission duration, the financial and scientific significance of the mission, the lack of studies regarding the impact of potentially small deposits on the wavefront [12] and the estimation of the LISA working group that even a 2 nm deposit will start affecting the detection performance adversely (see Figure 1), lead to the conclusion that a comprehensive de-risking activity is crucial.…”
Section: Introductionmentioning
confidence: 99%
“…An initial series of parametric tests with varying contamination source temperature, test duration and fluence showed no indications for LIC deposit formation [12]. Thus, a 6-month long duration test was intended and a new sample holder was developed, which superposes 8 optics under test in order to improve the sensitivity for in-situ detection of thin deposits.…”
Section: Introductionmentioning
confidence: 99%