2001
DOI: 10.1002/aic.690470521
|View full text |Cite
|
Sign up to set email alerts
|

Molecular simulation of adsorption: Gibbs dividing surface and comparison with experiment

Abstract: At low temperature near the normal boiling point, computer simulations of adsorption of gases can be compared directly with experiment. However, for adsorptive gas separations in which the gas is adsorbed near or above its critical temperature, absolute simulation variables must be converted to excess variables for comparison with experiment. The conversion of absolute to excess variables requires the helium pore volume of the adsorbent. Lennard‐Jones potential parameters for helium gas molecules interacting w… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
168
0
1

Year Published

2002
2002
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 219 publications
(172 citation statements)
references
References 17 publications
3
168
0
1
Order By: Relevance
“…Talu and Myers [25] proposed a simulation methodology that mimics the experimental procedure. For consistency with experiment, the helium void fraction j is determined by probing the framework with a helium molecule using the Widom particle insertion method:…”
Section: Surface Area Void Fraction and Pore-size Distributionmentioning
confidence: 99%
See 1 more Smart Citation
“…Talu and Myers [25] proposed a simulation methodology that mimics the experimental procedure. For consistency with experiment, the helium void fraction j is determined by probing the framework with a helium molecule using the Widom particle insertion method:…”
Section: Surface Area Void Fraction and Pore-size Distributionmentioning
confidence: 99%
“…Excess adsorption is the number of molecules in the nanopores in excess of the amount that would be present in the pore volume at the equilibrium density of the bulk gas. [25,26] RASPA calculates absolute adsorption and, if the pore-volume fraction is given (can be computed separately), it also calculates the excess adsorption for convenience. With this type of modelling, the experimental results are well reproduced.…”
Section: Adsorption In the Npt Gibbs Ensemblementioning
confidence: 99%
“…We probed the coal structure with an LJ helium atom at millions of random points, Fig. 8 Comparison of the bulk density for CH 4 , C 2 H 6 , and CO 2 at a 308 K; b 370 K computed the energy difference with and without the particle, and estimated the average Boltzmann weight which directly corresponds to the void fraction (Talu and Myers 2001). In our simulation, all micropores are accessible because of the inherent feature of the MC method.…”
Section: Excess Sorptionmentioning
confidence: 99%
“…A cuto radius r cˆ1 3 A Ê corresponding to the length of one side of the unit cell has been used frequently. More conservative calculations use cuto radii of 19 A Ê [21] or 20 A Ê [22]. In one simulation [23], a cuto radius of 8 A Ê was used to speed up the calculation.…”
Section: Adsorption In Silicalitementioning
confidence: 99%
“…We calculated the methane±oxygen radial distribution function shown in ®gure 3 using the potential par-ameters in table 1 and methods described elsewhere [22]. The complicated structure of the radial distribution function is a consequence of the anisotropic structure of silicalite, which consists of intersecting straight and zig-zag channels.…”
Section: Adsorption In Silicalitementioning
confidence: 99%