2010
DOI: 10.1021/la103010c
|View full text |Cite
|
Sign up to set email alerts
|

Molecular Understanding of Conformational Dynamics of a Fibronectin Module on Rutile (110) Surface

Abstract: The conformational dynamics of the 10th type-III module of fibronectin (FN-III(10)) adsorbed on the perfect and three reduced rutile TiO(2)(110) surfaces with different types of defects was investigated by molecular dynamics (MD) simulations. Stable protein-surface complexes were presented in the four simulated models and were derived from the contributions of direct and indirect interactions of various functional groups in FN-III(10) with the metal oxide layers. A detailed analysis to characterize the overall… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
30
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 30 publications
(30 citation statements)
references
References 45 publications
0
30
0
Order By: Relevance
“…The grounded flat copper collection plate was kept at a distance of 25 cm from the charged needle tip. A syringe pump (Braintree Scientific Co., Braintree, MA) was used to feed polymer solution into the needle at a feed rate of 0.05 mL min 21 .…”
Section: Scaffold Electrospinningmentioning
confidence: 99%
See 1 more Smart Citation
“…The grounded flat copper collection plate was kept at a distance of 25 cm from the charged needle tip. A syringe pump (Braintree Scientific Co., Braintree, MA) was used to feed polymer solution into the needle at a feed rate of 0.05 mL min 21 .…”
Section: Scaffold Electrospinningmentioning
confidence: 99%
“…Before performing the MD simulation, each system is optimized using Smart algorithm which is a cascade of the steepest descent, adopted basis Newton-Raphson, and quasi-Newton method. Ewald is the summation method used for electrostatic interactions with accuracy of 0.001 kcal mol 21 , and for Van der Waals an atom-based summation is used with truncation of atoms, further than the cutoff distance of 12.5 Å. All the polymer surface atoms are fixed while the protein can move freely.…”
Section: Simulationsmentioning
confidence: 99%
“…21−23 The effect of surface defects on protein adsorption behavior could be particularly important because the surface topology may affect the biological activity of adsorbed proteins. 24,25 Protein−surface interactions are a fundamental issue in various fields and devices. The orientation of an adsorbed protein on a medical device, for example, greatly determines the activity of the protein.…”
Section: Introductionmentioning
confidence: 99%
“…Other analyses included the general structure of the protein itself, which was characterized by parameters such as the root-mean-square deviation of the adsorbed protein compared to its native structure, the protein's radius of gyration, and the orientation of the protein's dipole moment with respect to the surface plane. Others have investigated the influence of adsorption on the structure and orientation of the arginine-glycine-aspartic acid (RGD) loop of fibronectin on various types of surfaces as an approach to assess the availability of this bioactive site for cell-receptor binding [74,75]. …”
Section: Methodsmentioning
confidence: 99%