2020
DOI: 10.1039/d0ra04785f
|View full text |Cite
|
Sign up to set email alerts
|

Molecularly imprinted polymeric coatings for sensitive and selective gravimetric detection of artemether

Abstract: Chemical structures of the antimalarial drugs: artemisinin, artemether (a methyl ether derivative of artemisinin), and lumefantrine.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 15 publications
(9 citation statements)
references
References 37 publications
0
9
0
Order By: Relevance
“…Then, Ti 3 C 2 T x @CuFc-MOF/MIP is synthesized with polymerizing the MIP on the Ti 3 C 2 T x @CuFc-MOF. As illustrated in Figure d, Ti 3 C 2 T x @CuFc-MOF/MIP exhibited characteristic peaks of methacrylic acid (functional molecules of MIP) at 1728 and 1159 cm –1 , indicating the successful loading of the MIP on the heterostructure . It could also be observed from Figure S9a,b that abundant and dense MIPs are uniformly dispersed on the Ti 3 C 2 T x @CuFc-MOF.…”
Section: Resultsmentioning
confidence: 99%
“…Then, Ti 3 C 2 T x @CuFc-MOF/MIP is synthesized with polymerizing the MIP on the Ti 3 C 2 T x @CuFc-MOF. As illustrated in Figure d, Ti 3 C 2 T x @CuFc-MOF/MIP exhibited characteristic peaks of methacrylic acid (functional molecules of MIP) at 1728 and 1159 cm –1 , indicating the successful loading of the MIP on the heterostructure . It could also be observed from Figure S9a,b that abundant and dense MIPs are uniformly dispersed on the Ti 3 C 2 T x @CuFc-MOF.…”
Section: Resultsmentioning
confidence: 99%
“…We calculated the limit of detection (LoD) as 3.3 × (standard deviation of the intercept)/slope and the limit of quantification LoQ as 10 × (standard deviation of the intercept)/slope [ 40 ]. The standard deviation of this sensor was 17.7 Hz and the slope was 10.944, resulting in LoD values of 5.3 μg/mL (80 nM) and LoQ of 16.2 μg/mL (244 nM).…”
Section: Resultsmentioning
confidence: 99%
“…E5062A). The change of frequencies and damping values before/after coating and after washing the polymer was recorded and allowed us to estimate the respective layers' heights based on the experience of the group [31]. In addition, removal of the template molecules from the MIP film was also monitored by the network analyzer: Successful removal resulted in an increase of the resonance frequency of QCM after washing.…”
Section: Coating Process Of Thin Films On Qcmmentioning
confidence: 99%