2012
DOI: 10.1021/ac302048x
|View full text |Cite
|
Sign up to set email alerts
|

MolFind: A Software Package Enabling HPLC/MS-Based Identification of Unknown Chemical Structures

Abstract: In this paper, we present MolFind, a highly multi-threaded pipeline type software package for use as an aid in identifying chemical structures in complex biofluids and mixtures. MolFind is specifically designed for high performance liquid chromatography/mass spectrometry (HPLC/MS) data inputs typical of metabolomics studies where structure identification is the ultimate goal. MolFind enables compound identification by matching HPLC/MS based experimental data obtained for an unknown compound with computationall… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
80
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 65 publications
(81 citation statements)
references
References 37 publications
0
80
0
Order By: Relevance
“…Also, most of the chemometric predictive models in literature use positive ionization, for instance a chemometric tool for prediction of drift times in positive mode has been previously described [20], and relatively few CCS measurements have been done for negatively charged ions [21]. This is unfortunate especially because many small metabolites such as phenolics ionize better in negative ionization mode.…”
Section: Introductionmentioning
confidence: 99%
“…Also, most of the chemometric predictive models in literature use positive ionization, for instance a chemometric tool for prediction of drift times in positive mode has been previously described [20], and relatively few CCS measurements have been done for negatively charged ions [21]. This is unfortunate especially because many small metabolites such as phenolics ionize better in negative ionization mode.…”
Section: Introductionmentioning
confidence: 99%
“…For a more detailed discussion of relevance and the Boruta algorithm see Kohavi and John (1997) and Rudnicki et al (2015). This algorithm has been used in different fields, including bioinformatics, remote sensing, bacteriology and medicine (Aagaard et al, 2012;Ackerman et al, 2013;Buday et al, 2013;Duro et al, 2012;Herrera and Bazaga, 2013;Leutner et al, 2012;Ma et al, 2014;Menikarachchi et al, 2012;Saulnier et al, 2011;Strempel et al, 2013).…”
Section: Methodsmentioning
confidence: 99%
“…Limited metabolite coverage is obtained when using data-dependent modes since only intense ions are fragmented and many artifact ions will be detected and fragmented due to the inherent presence of isotopes, in-source fragments or high abundance ions from contamination or chemical noise [53]. Resources to annotate MS/MS spectra by comparison with experimental [53] or in-silico spectral libraries have been proposed, including MolFind [54], MetFrag [60], MetFusion [55], MyCompoundID [56, 57], CFM-ID [58] and MS-FINDER [59]. Alternatively, data-independent acquisition (DIA) modes such as MS E [62] or SWATH [63], in which all fragment ions for all precursors are simultaneously acquired, allows an increased MS/MS spectral coverage and reinforces the annotation confidence [64].…”
Section: Computational Annotation Strategiesmentioning
confidence: 99%