Monitoring harmonic distortion in microgrids using dynamic mode decomposition

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(3 citation statements)
references
References 17 publications
0
3
0
Order By: Relevance
“…DMD is one of the data-driven methods that has the potential to be used in the power system application due to its robustness and estimation speed. Specifically, DMD has been used for electromechanical oscillation monitoring [2][3][4][5][6][7][8][9][10][11][12][13][14][15][16] estimation of inertia [17] and frequency [18,19], harmonic distortion monitoring [20,21], fault detection [22], load forecasting [23][24][25] and data-driven control for enhancing rotor angle stability [26,27]. Regarding the oscillation monitoring using DMD, there are still some challenges related to the amount of input data that need to be addressed for achieving real-time oscillation monitoring.…”
Section: Motivationmentioning
confidence: 99%
“…DMD is one of the data-driven methods that has the potential to be used in the power system application due to its robustness and estimation speed. Specifically, DMD has been used for electromechanical oscillation monitoring [2][3][4][5][6][7][8][9][10][11][12][13][14][15][16] estimation of inertia [17] and frequency [18,19], harmonic distortion monitoring [20,21], fault detection [22], load forecasting [23][24][25] and data-driven control for enhancing rotor angle stability [26,27]. Regarding the oscillation monitoring using DMD, there are still some challenges related to the amount of input data that need to be addressed for achieving real-time oscillation monitoring.…”
Section: Motivationmentioning
confidence: 99%
“…Recently, DMD has been explored for harmonics monitoring applications. In [21], harmonics monitoring in MGs is performed using DMD by utilizing its spatio-temporal decomposition ability. A novel methodology for harmonics identification using DMD is proposed in [1] using singular value thresholding.…”
Section: Dynamic Mode Decompositionmentioning
confidence: 99%
“…That work has been mainly focused on the global dynamics of the electric grid. DMD has also been used for monitoring distortion of power system signals in microgrids [33].…”
Section: Introductionmentioning
confidence: 99%