Monitoring of high-flow nasal cannula for SARS-CoV-2 severe pneumonia: less is more, better look at respiratory rate

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
55
0
2

Year Published

2020
2020
2023
2023

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 47 publications
(60 citation statements)
references
References 7 publications
3
55
0
2
Order By: Relevance
“…When you reach FiO2 of 40%, decrease flow until weaning. 40 However an ideal weaning protocol remains to be established. A current RCT 41 is studying 3 different protocols: 1) gradually wean flow by 10 L/min/h.…”
Section: Criteria Of Hfnc Weaningmentioning
confidence: 99%
“…When you reach FiO2 of 40%, decrease flow until weaning. 40 However an ideal weaning protocol remains to be established. A current RCT 41 is studying 3 different protocols: 1) gradually wean flow by 10 L/min/h.…”
Section: Criteria Of Hfnc Weaningmentioning
confidence: 99%
“…Respiratory rate-oxygenation (ROX) was defined as the ratio of SpO 2 /FIO 2 to respiratory rate (18,23). HFNC therapy failure was defined as need for MV within 7 days of HFNC initiation (24). The criteria for typical HFNC failures include failures to maintain SpO 2 >90%, hypercapnic respiratory failures with pH <7.2 or PaCO 2 of arterial blood >55 mm Hg, worsening respiratory distress, or need for airway protection due to altered mental state or aspiration (10,14,15,18,19).…”
Section: Definitionsmentioning
confidence: 99%
“…At HFNC initiation, compared with patients in the HFNC success group, the HFNC failure group had a higher level of D-dimer [ (20)(21)(22)(23)(24) vs. 23 (22)(23)(24)(25); p < 0.001] ( Table 2), but no differences in systolic arterial pressure were observed between the two groups. The RR alone had an AUC of 0.65 (0.59-0.71).…”
Section: Demographic Data and Clinical Parameters Of Included Patientsmentioning
confidence: 99%
See 1 more Smart Citation
“…The accuracy of multiple monitoring parameters in predicting HFNC failure in COVID-19-related AHRF was assessed in one study, where RR ≥ 26/min after half an hour of HFNC application was associated with a higher risk of HFNC failure. However, the study was limited by small sample size (32 patients) and high SpO 2 (100%) observed in a third of their cohort, which could participate in decreasing the contribution of SpO 2 /FiO 2 in the diagnostic accuracy of ROX [21].…”
Section: Discussionmentioning
confidence: 96%