2015
DOI: 10.1111/jon.12322
|View full text |Cite
|
Sign up to set email alerts
|

Monitoring of Intracranial Pressure by CT‐Defined Optic Nerve Sheath Diameter

Abstract: In its narrowest part, the average OC is 11 to 16.75 mm² wide. We suggest measuring this area simultaneously with the ONSD during ICP monitoring. If the area of the narrowest lumen of the canal is less than 10 mm², ONSD technique for ICP monitoring should not be used.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

2
17
0
1

Year Published

2016
2016
2021
2021

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(20 citation statements)
references
References 21 publications
2
17
0
1
Order By: Relevance
“…Jiang et al ’s study reviewed optic canal CT images of 100 healthy volunteers using 2.5 mm slice thickness, reconstructed 0.625 mm thickness and showed that the narrowest part of the optic canal tends to be in the middle of the canal 8. Another study using CT images from 300 healthy volunteers found a minimum cross-sectional area of 13.85±2.89 mm 2 with a range of 11 to 16.75 mm 2 , which are similar to our findings 15. Lee et al investigated comparisons of the narrowest cross-sectional area of the optic canal between 38 patients with fibrous dysplasia and 38 healthy controls and found an average area of 11.9±2.8 mm 2 in the control group, also comparable with our findings.…”
Section: Discussionsupporting
confidence: 91%
See 2 more Smart Citations
“…Jiang et al ’s study reviewed optic canal CT images of 100 healthy volunteers using 2.5 mm slice thickness, reconstructed 0.625 mm thickness and showed that the narrowest part of the optic canal tends to be in the middle of the canal 8. Another study using CT images from 300 healthy volunteers found a minimum cross-sectional area of 13.85±2.89 mm 2 with a range of 11 to 16.75 mm 2 , which are similar to our findings 15. Lee et al investigated comparisons of the narrowest cross-sectional area of the optic canal between 38 patients with fibrous dysplasia and 38 healthy controls and found an average area of 11.9±2.8 mm 2 in the control group, also comparable with our findings.…”
Section: Discussionsupporting
confidence: 91%
“…Bekerman et al measured CT scans from 300 volunteers and found that the average minimum diameter at the minimal area of the optic canal is 4.2±1.7 mm for circular lumens and 4.0±1.6 mm for oval lumens,15 which are somewhat larger but still comparable to our average of 3.28±0.55 mm. Jiang et al 8 measured multiple layers through the optic canal and found a minimum diameter of 4.86±0.26 mm on the left and 4.91±0.30 mm on the right which is slightly larger than our measurements, likely as a result of averaging measurements at each set slice rather averaging results at the narrowest portion of each canal.…”
Section: Discussionsupporting
confidence: 81%
See 1 more Smart Citation
“…34 While ONSD has been proven effective in patients with IIH, Bekerman et al noted a potential limitation with the ONSD method in that, cases with narrow optic canal lumen (< 10 mm 2 ) result in false-negative tests and conclude that if the lumen of the canal is < 10 mm 2 , the ONSD method should not be used. 37 It should also be noted that one study found the ONSD method of ICP measurement was unreliable, with sensitivity and specificity values of 36 and 38%, respectively. 35 Despite these findings as well as the fact that invasive ICP measurement via lumbar puncture remains the gold standard, measurement of ONSD has overall demonstrated efficacy and offers an efficient, cost-effective, noninvasive method of diagnosis and monitoring of ICP in patients with IIH.…”
Section: Noninvasive Diagnostics and Monitoring Noninvasive Measuremementioning
confidence: 99%
“…mm2 as patients with narrow canals had false negative readings, prior to using ONSD to predict ICP may improve the sensitivity of this method 58. In physiological conditions, the relaxed septum pallucidum undulates at higher amplitudes than the surrounding structures.…”
mentioning