Monitorización intraoperatoria del bloqueo neuromuscular y la presión arterial con un solo dispositivo (TOF-Cuff): estudio comparativo con la mecanomiografía y la presión arterial invasiva

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0
1

Year Published

2018
2018
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 20 publications
(5 citation statements)
references
References 68 publications
0
4
0
1
Order By: Relevance
“…Finally, we did not monitor the performance of the cuff pressure of the TOF-Cuff device because we had too few time points to conduct assessments during anaesthetic induction. However, Veiga Ruiz et al [5] found that the arterial blood pressure monitoring was sufficient and in accordance with European standard 93/42/EEC.…”
Section: Discussionmentioning
confidence: 64%
See 1 more Smart Citation
“…Finally, we did not monitor the performance of the cuff pressure of the TOF-Cuff device because we had too few time points to conduct assessments during anaesthetic induction. However, Veiga Ruiz et al [5] found that the arterial blood pressure monitoring was sufficient and in accordance with European standard 93/42/EEC.…”
Section: Discussionmentioning
confidence: 64%
“…and use, no prerequisite of "ideal positioning" of the lower arm, and the elimination of expensive components sometimes required by standard monitors. The use of this newly released device has been described, but its merits, when compared to standard devices, have not been tested extensively [5].…”
mentioning
confidence: 99%
“…In this set of experiments, we carefully performed the free parameters fine-tuning of previously mentioned algorithms specifically for the device characteristics, in order to meet the clinical requirements given by expert clinicians from University Hospital Virgen de la Arrixaca of Murcia. The ABP technology integrated into the VM1 had been previously validated by RGB manufacturer in precedent works [34,35]. They tested the ABP sensor over 17 adult patients by comparing it with an invasive ABP measurement taken by an intra-arterial catheter.…”
Section: Experiments and Resultsmentioning
confidence: 99%
“… 33 In a 2017 study comparing TOF-Cuff with MMG and with invasive blood pressure measurement, TOF-Cuff was shown to be effective and safe in monitoring neuromuscular blockade and NIBP (Non-Invasive Blood Pressure), but it cannot be used interchangeably with MMG. 34 In a study by Markle et al from 2017, technical problems were highlighted. Among the 56 patients participating in the study, technical problems occurred at least once in 14 patients in the TOF-Cuff measurements and in 7 patients in the TOF-Scan measurements.…”
Section: Main Sectionsmentioning
confidence: 99%