2017
DOI: 10.1103/physrevaccelbeams.20.024701
|View full text |Cite
|
Sign up to set email alerts
|

Monochromaticity of coherent Smith-Purcell radiation from finite size grating

Abstract: Investigation of coherent Smith-Purcell Radiation (SPR) spectral characteristics was performed both experimentally and by numerical simulation. The measurement of SPR spectral line shapes of different diffraction orders was carried out at KEK LUCX facility. A pair of room-temperature Schottky barrier diode (SBD) detectors with sensitivity bands of 60 − 90 GHz and 320 − 460 GHz was used in the measurements. Reasonable agreement of experimental results and simulations performed with CST Studio Suite justifies th… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 17 publications
(7 citation statements)
references
References 29 publications
0
7
0
Order By: Relevance
“…3(a) and 3(b), we obtain that Δλ∕λ Γ are 0.0356% and 0.0175% for the cases with E f 0.23 eV and E f 0.7 eV, respectively, which is much less than the relative linewidth (about 1% in Ref. [65]). This means that the TH conversion efficiency is low when the frequency is taken at the deviation of the BICs.…”
Section: A Numerical Results For the Th Generation Based On Bicsmentioning
confidence: 78%
“…3(a) and 3(b), we obtain that Δλ∕λ Γ are 0.0356% and 0.0175% for the cases with E f 0.23 eV and E f 0.7 eV, respectively, which is much less than the relative linewidth (about 1% in Ref. [65]). This means that the TH conversion efficiency is low when the frequency is taken at the deviation of the BICs.…”
Section: A Numerical Results For the Th Generation Based On Bicsmentioning
confidence: 78%
“…The noncentral propagation of the beam in the corrugated capillary yielded 10-fold increase in the radiation intensity. Issues that remain to be considered in the future work are further investigations of how sensitive is the radiation directivity pattern to the transverse beam position; studies of the beam dynamics during and after propagation through the capillaries; and spectral measurements for a single and a multi-bunch beam, similar to the measurements described in [16].…”
Section: Discussionmentioning
confidence: 99%
“…Figure 4 shows a schematic diagram of the experimental setup. The LUCX is a multipurpose linear electron accelerator that was initially designed as an rf gun test bench and later extended for two projects: one to develop an x-ray source based on Compton scattering [25,26] and one to investigate coherent radiation [27][28][29][30][31]. The LUCX consists of a high mode separation 3.6 cell rf gun with a Cs 2 Te photocathode [32] and a normal conductivity 1 m 12-cell mode-separated linac booster [27].…”
Section: Methodsmentioning
confidence: 99%