Montage electron tomography of vitrified specimens

Abstract: Cryo-electron tomography provides detailed views of macromolecules in situ. However, imaging a large field of view to provide more cellular context requires reducing magnification during data collection, which in turn restricts the resolution. To circumvent this trade-off between field of view and resolution, we have developed a montage data collection scheme that uniformly distributes the dose throughout the specimen. In this approach, sets of slightly overlapping circular tiles are collected at high magnific… Show more

Help me understand this report
View published versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

1
5
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 38 publications
1
5
0
Order By: Relevance
“…This departure in image shift values introduced by global tile rotation was much larger than the applied translation alone at lower tilts and became particularly irregular as the stage was tilted to degrees greater than ±30°. As a result, the inconsistent overlap between tiles caused problematic stitching, consistent with previous reports 15,18 .…”
supporting
confidence: 89%
See 2 more Smart Citations
“…This departure in image shift values introduced by global tile rotation was much larger than the applied translation alone at lower tilts and became particularly irregular as the stage was tilted to degrees greater than ±30°. As a result, the inconsistent overlap between tiles caused problematic stitching, consistent with previous reports 15,18 .…”
supporting
confidence: 89%
“…Compared to resin-embedded samples where the image contrast is strong 18 , reliable tile overlaps at a majority of the tilts are essential in vitrified unstained samples to achieve gap-free stitching 15 . 4) Sorting of individual tile tilt series from the complete montage collection for efficient data processing and sub-tomogram averaging is applicable only when each tile frame contains enough fringe-unimpacted FOV and retains the ROI throughout the tilt series.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…Camera size improvements can impact the resolution achieved but not the number of extracted particles ( Kudryashev et al, 2012 ). To overcome such a trade-off between resolution and FOV, montage data collection schemes are being explored for cryo-ET ( Peck et al, 2021 ; Yang et al, 2022 ). These approaches are especially useful for lamellae where, after a timely workflow to obtain them, the maximum information can be extracted by imaging the lamella as much as possible .…”
Section: Resolution Vs Field Of Viewmentioning
confidence: 99%
“…Relevant ongoing developments that help expand cryo-ET are pointed out by a black arrow at their corresponding length scale area. Montage ET allows image acquisition of larger field of views (FOV) without compromising resolution at the cost of elongated acquisition times ( Peck et al, 2021 ; Yang et al, 2022 ). While microfluidic cryofixation of larger specimens during live-cell microscopy imaging is a promising tool to explore the opportunities for correlative light and electron microscopy studies ( Fuest et al, 2019 ).…”
Section: Introductionmentioning
confidence: 99%