2015
DOI: 10.1016/j.apradiso.2014.09.007
|View full text |Cite
|
Sign up to set email alerts
|

Monte Carlo analysis of the influence of germanium dead layer thickness on the HPGe gamma detector experimental efficiency measured by use of extended sources

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0
3

Year Published

2015
2015
2023
2023

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 30 publications
(12 citation statements)
references
References 6 publications
0
9
0
3
Order By: Relevance
“…There is also a certain uncertainty in the crystal parameters e.g. the dead layer thicknesses [34] or the distance between end cap and Ge crystal. It has also been observed, that there can be a substantial increase of the dead layer thickness after some years of operating time [35].…”
Section: Efficiency Of the Detectormentioning
confidence: 99%
“…There is also a certain uncertainty in the crystal parameters e.g. the dead layer thicknesses [34] or the distance between end cap and Ge crystal. It has also been observed, that there can be a substantial increase of the dead layer thickness after some years of operating time [35].…”
Section: Efficiency Of the Detectormentioning
confidence: 99%
“…Some techniques for evaluating the efficiency calibration of a detector include the implementation of Monte Carlo simulation (MCS) (Ewa, Bodizs, Czifrus, & Molnar, 2001;Rodenas, Martinavarro, & Rius, 2000;Vidmar & Vodenik, 2010) or a combination of both MCS and genetic algorithms (Quang, Do, & Vo, 2012). In MCS, it is important to have detailed information about the configuration, dimensions, and constituent materials of the detector, which are usually different from the manufacturer's specifications (Andreotti et al, 2014), especially in the case of old detectors that have dead layer formation, as noted in HPGe detectors (Chham et al, 2015;Rodenas et al, 2003).…”
Section: Introductionmentioning
confidence: 99%
“…In a sep a rate work, Dryak and Kovar [20] used a collimated pho ton beam of 59.5 keV from an Am-241 source from var i ous in ci dence an gles on the front face of an HPGe de tec tor to de ter mine the ef fec tive thickness of the dead layer. Like wise, many re search ers found it nec es sary to op ti mize the dead layer thick ness in or der to re move dis crep an cies be tween ex per i mental ob ser va tions and cor re spond ing Monte Carlo sim ulated val ues [21][22][23][24][25][26][27][28][29][30][31].…”
Section: Introductionmentioning
confidence: 99%