2021
DOI: 10.1002/mp.14726
|View full text |Cite
|
Sign up to set email alerts
|

Monte Carlo computation of 3D distributions of stopping power ratios in light ion beam therapy using GATE‐RTion

Abstract: This paper presents a novel method for the calculation of three-dimensional (3D) Bragg-Gray water-to-detector stopping power ratio (s w,det ) distributions for proton and carbon ion beams. Methods: Contrary to previously published fluence-based calculations of the stopping power ratio, the s w,det calculation method used in this work is based on the specific way GATE/Geant4 scores the energy deposition. It only requires the use of the so-called DoseActor, as available in GATE, for the calculation of the s w,de… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 38 publications
0
3
0
Order By: Relevance
“…The quantity p dis was calculated by Dair/Dcav${D}_{{\rm{air}}}/{D}_{{\rm{cav}}}$, where D air is absorbed dose to a thin cylindrical air slab (1‐cm radius and 250 μm thickness), and D cav is the absorbed dose to the air cavity of the IC without any other subcomponents present. The p cav correction factor was not reported in this study as it is independent of the IC model/type and requires calculation of water‐to‐air stopping power ratios, which was outside the scope of this work and has been studied elsewhere for ICRU report 90 data 23,34 …”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The quantity p dis was calculated by Dair/Dcav${D}_{{\rm{air}}}/{D}_{{\rm{cav}}}$, where D air is absorbed dose to a thin cylindrical air slab (1‐cm radius and 250 μm thickness), and D cav is the absorbed dose to the air cavity of the IC without any other subcomponents present. The p cav correction factor was not reported in this study as it is independent of the IC model/type and requires calculation of water‐to‐air stopping power ratios, which was outside the scope of this work and has been studied elsewhere for ICRU report 90 data 23,34 …”
Section: Methodsmentioning
confidence: 99%
“…The p cav correction factor was not reported in this study as it is independent of the IC model/type and requires calculation of water-to-air stopping power ratios, which was outside the scope of this work and has been studied elsewhere for ICRU report 90 data. 23,34…”
Section: Perturbation Correction Factormentioning
confidence: 99%
“…To illustrate this phenomenon, www.nature.com/scientificreports/ we have selected two pertinent studies that effectively highlight the impact of different materials. A study 46 was conducted to investigate the water-to-detector stopping power ratio for the plateau region. Additionally, the influence of the quartz window on the Peakfinder was investigated through comprehensive studies conducted at Heidelberg 47 .…”
Section: Clinical Evaluation With Photon and Proton/carbon Ion Beamsmentioning
confidence: 99%
“…Current hot topics in the field of proton and carbon ion therapy, such as variable proton Relative Biological Effectiveness (RBE) depending on Linear Energy Transfer (LET) [136] (see next sections), the influence of fragmentation spectra on carbon ion RBE [115], influence of new stopping power tables (e.g. ICRU90) for 3D dosimetric applications with protons and carbon ions [22] are fully supported by the Gate-RTion release.…”
Section: Dose-related Applicationsmentioning
confidence: 99%