Monte Carlo dosimetry of the eye plaque design used at the St. Erik Eye Hospital for 125I brachytherapy

Abstract: 1 AbstractPurpose: At St. Erik Eye Hospital in Stockholm, ocular tumors of apical height >6 mm are treated with brachytherapy, using 125 I seeds attached to a gold alloy plaque while the treatment planning is performed assuming homogeneous water surroundings. The aim of this work was to investigate the dose modifying effects of the plaque and the seed fixating silicone rubber glue. Methods and materials:The impact of the gold plaque and the silicone rubber glue was studied with the Monte Carlo code MCNP5. Resu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

1
1
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(2 citation statements)
references
References 20 publications
1
1
0
Order By: Relevance
“…When using the TPS for calculation of dose, the stent and the medium around it are simulated as water, ignoring the structure inhomogeneities with only limited dose uncertainties. [25] The TPS in this study calculated the dose using point source simulations, which in fact agreed to be within about 2% with the full geometric simulations at all distances between 1 cm and 10 cm;[26] thus, within this practical range, TPS agrees very well with the TLD measurements and MCNPX. Therefore, the TPS utilized by us can be reliably used for clinical applications involving biliary stents.…”
Section: Discussionsupporting
confidence: 67%
“…When using the TPS for calculation of dose, the stent and the medium around it are simulated as water, ignoring the structure inhomogeneities with only limited dose uncertainties. [25] The TPS in this study calculated the dose using point source simulations, which in fact agreed to be within about 2% with the full geometric simulations at all distances between 1 cm and 10 cm;[26] thus, within this practical range, TPS agrees very well with the TLD measurements and MCNPX. Therefore, the TPS utilized by us can be reliably used for clinical applications involving biliary stents.…”
Section: Discussionsupporting
confidence: 67%
“…It offers equivalent tumor control and better quality of life such as eye preservation and vision retention in comparison to enucleation [ 3 5 ]. Various plaque designs were proposed and are clinically used in major institutions [ 6 8 ]. Nonetheless, Collaborative Ocular Melanoma Study (COMS) plaques have been widely used in most clinics since the COMS established standardized methods of plaque brachytherapy for medium-sized choroidal melanomas [ 3 ].…”
Section: Introductionmentioning