Monte-Carlo modeling of a NaI(Tl) scintillator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
6
2
1

Relationship

1
8

Authors

Journals

citations
Cited by 17 publications
(8 citation statements)
references
References 1 publication
0
8
0
Order By: Relevance
“…The energy spectrum was also acquired with the FLUKA MC programme and the theoretical energy resolution was found to be 6.77% (Figure 11). Ashrafi et al obtained the 137 Cs gamma energy spectrum by means of the GEANT4 MC method [16]. When a comparison was made between their theoretical spectrum and the one in this work, it was seen that the K X-ray peak was available in the presented spectrum via FLUKA MC method.…”
Section: K X-ray Peak Photopeakmentioning
confidence: 58%
See 1 more Smart Citation
“…The energy spectrum was also acquired with the FLUKA MC programme and the theoretical energy resolution was found to be 6.77% (Figure 11). Ashrafi et al obtained the 137 Cs gamma energy spectrum by means of the GEANT4 MC method [16]. When a comparison was made between their theoretical spectrum and the one in this work, it was seen that the K X-ray peak was available in the presented spectrum via FLUKA MC method.…”
Section: K X-ray Peak Photopeakmentioning
confidence: 58%
“…MC simulation was used to determine gamma-ray response functions of a NaI(Tl) detector by Shi et al [15]. The theoretical energy spectrum of 137 Cs was given by Ashrafi et al via the Geant4 MC method [16].…”
Section: Input F Lementioning
confidence: 99%
“…It is also used in the characterization of the detector system which is the most important part of the positron emission tomography (PET), etc. GATE runs with Geant4 simulation toolkit which is the validated physics models, complex geometrical volume description and powerful 3D visualization (such as Qt mode) [8,[19][20][21][22][23].…”
Section: Introductionmentioning
confidence: 99%
“…There are two faces through which photons can hit a typical NaI (Tl) detector: circular side so-called the detector's entrance window and cylindrical side. In gamma spectrometry, in order to gauge the radioactive contamination originated from different directions of the environment, the cylindrical side of sodium iodide detector is modelled [4], whereas, in laboratorial measurement in which the position of a radiation source in relative to detector is well-defined, shielding of the detector in order to minimize the background radiation is welcome [5]. In radiation measurements, the detection efficiency is an important quantity, so that in the absence of a reliable value for detection efficiency, accurate data analysis is impossible [6,7].…”
Section: Introductionmentioning
confidence: 99%