1993
DOI: 10.1016/0168-9002(93)91284-t
|View full text |Cite
|
Sign up to set email alerts
|

Monte Carlo simulation of several gamma-emitting source and detector arrangements for determining corrections of self-attenuation and coincidence summation in gamma-spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0

Year Published

1993
1993
2018
2018

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 35 publications
(9 citation statements)
references
References 3 publications
0
9
0
Order By: Relevance
“…As the sediment samples studied have densities within the interval 0.8-1.7 g/cm 3 , the linear attenuation  is, therefore, higher for the most dense samples. For every sample M having a density  M , the linear attenuation is then (14) It must be indicated that the existence of a common value of  mas for a set of samples extracted from a determined environment is not always fulfi lled. In particular, this common coeffi cient does not exist when samples show very different compositions or when there are high variations in the granulometry among the samples [11].…”
Section: Mass Attenuation Coeffi Cient Of Sediment Samplesmentioning
confidence: 99%
“…As the sediment samples studied have densities within the interval 0.8-1.7 g/cm 3 , the linear attenuation  is, therefore, higher for the most dense samples. For every sample M having a density  M , the linear attenuation is then (14) It must be indicated that the existence of a common value of  mas for a set of samples extracted from a determined environment is not always fulfi lled. In particular, this common coeffi cient does not exist when samples show very different compositions or when there are high variations in the granulometry among the samples [11].…”
Section: Mass Attenuation Coeffi Cient Of Sediment Samplesmentioning
confidence: 99%
“…However, real point source emit photons having the angle distribution is 4. For this reason, the total efficiency of detector for the point sourcedetector arrangement was determined as follows [2]:…”
Section: Trang 28mentioning
confidence: 99%
“…In addition to analytical method, Monte Carlo method was also used to determine the total efficiency of NaI(Tl) crystal because of the simplicity of this method [2,5].…”
Section: Introductionmentioning
confidence: 99%
“…These pioneering works were followed by new developments: Monte Carlo simulation was used by Decombaz (Decombaz et al, 1992) for coincidence summing correction. Later the correction factors were determined with a mixture of Monte Carlo simulation for computing efficiencies and numerical computation of the corrective factors (Sima and Arnold, 2000;Haase et al, 1993). Furthermore, different practical approaches were developed by a number of authors such as Solc et al (in press), Xie et al (2014), Sahiner and Meric (2014), Tomatchino andRizzo (2011), Jutier et al (2007) and Vidmar and Korun (2006).…”
Section: Introductionmentioning
confidence: 99%